Probing Disk Drives - Avaya Sun Fire V880 Installation & Maintenance

Hardware installation, maintenance, and troubleshooting
Hide thumbs Also See for Sun Fire V880:
Table of Contents

Advertisement

Troubleshooting

Probing disk drives

This test checks all disk drives.
Symptom: The internal disk drives are reporting errors.
Solution: To check the status of the disk drives:
1. Enter:
/usr/sbin/shutdown -y -i0 -g0
This shuts down the system.
2. At the ok prompt, enter the following commands:
setenv auto-boot? false
reset-all
The system resets.
3. Enter:
probe-scsi
The program displays a message that is similar to the following:
LiD HA LUN
0
0
0
1
1
0
2
2
0
6
6
0
3
3
0
4
4
0
5
5
0
Note:
The actual response depends on the number of disk drives that are installed in
Note:
the system. This example shows six disk drives and the disk drive backplane.
4. Fix any obvious errors, such as disconnected backplane cables or disk drives not
completely inserted.
5. When you finish testing, enter the following commands:
!
CAUTION:
If you fail to enter these commands, any reboots that you do in the future will stop
CAUTION:
at the boot prompt instead of proceeding through the normal boot-up process.
setenv auto-boot? true
boot -r
The system reboots.
168
Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting
--- Port WWN ---
-----Disk description -----
21000004cf72f08f
SEAGATE ST373405FSUN3660438
21000004cf721553
SEAGATE ST373405FSUN3660438
21000004cf7213ea
SEAGATE ST373405FSUN3660438
508002000016b5b1
SUNW
21000004cf72114b
SEAGATE ST373405FSUN3660438
21000004cf7211ae
SEAGATE ST373405FSUN3660438
21000004cf7214a3
SEAGATE ST373405FSUN3660438
SUNWGS INT FCBPL9224
May 2006