Troubleshooting Disk Drives And Dvd Drives - Avaya Sun Fire V880 Installation & Maintenance

Hardware installation, maintenance, and troubleshooting
Hide thumbs Also See for Sun Fire V880:
Table of Contents

Advertisement

Troubleshooting

Troubleshooting disk drives and DVD drives

This section describes the symptoms of disk drive and DVD drive failures and suggests
solutions to correct the problem.
Symptom: The operating system reports a disk drive read, write, or parity error or reports a
DVD drive read error or parity error.
Solution: Replace the drive that is indicated in the failure message. The operating system
identifies the internal drives as shown in the following table.
system address
c1t<X>d0s0
c0t6d0s0
Symptom: The disk drive fails to respond to commands.
Solution: To test the disk drives:
1. Enter:
/usr/sbin/shutdown -y -i0 -g0
The system shuts down.
2. At the ok prompt, enter the following commands:
setenv auto-boot? false
reset-all
The system resets.
3. Enter:
probe-scsi
The program displays a message that is similar to the following:
LiD HA LUN
0
0
0
1
1
0
2
2
0
6
6
0
3
3
0
4
4
0
5
5
0
186
Avaya CMS Sun Fire V880/V890 Installation, Maintenance, and Troubleshooting
Operating
Disk drive, target <X> (<X> represents the target
number and slot number, 0 to 5)
DVD drive, target 6
--- Port WWN ---
-----Disk description -----
21000004cf72f08f
SEAGATE ST373405FSUN3660438
21000004cf721553
SEAGATE ST373405FSUN3660438
21000004cf7213ea
SEAGATE ST373405FSUN3660438
508002000016b5b1
SUNW
21000004cf72114b
SEAGATE ST373405FSUN3660438
21000004cf7211ae
SEAGATE ST373405FSUN3660438
21000004cf7214a3
SEAGATE ST373405FSUN3660438
Drive physical location and target
SUNWGS INT FCBPL9224
May 2006

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sun fire v890

Table of Contents