Agilent Technologies E1437A User Manual page 163

20 msample/second adc with filters and fifo
Table of Contents

Advertisement

E1437A
ASCII Overview and Commands
Example:
The following example shows how to initiate a measurement in a typical
multi-module system
! Place all HP E1437s in IDLE
!
! Take all HP E1437s out of IDLE
!
! Check for Sync/Idle complete on last module (if decimation is synchronous);
! Check all modules if decimation is not synchronous.
! Assert SYNC on master module to arm all modules
!
!Release SYNC to allow triggering by any module
Reset Values:
idle=RELEASE, sync=RELEASE
See Also:
STATUS?, DATA:SETUP, FILTER:SYNC, FREQUENCY:SYNC, CLOCK:SETUP
5-40
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
OUTPUT <addrAll>;"MEAS:CONTROL 1,0"
OUTPUT <addrAll>;"MEAS:CONTROL 0,0"
OUTPUT <addrAll>;"Status?
ENTER <addrAll> Result$
.....
OUTPUT <addrMaster>;"MEAS:CONTROL 0,1"
OUTPUT <addrMaster>;"MEAS:CONTROL 0,0"
MEAS:CONTROL
command

Advertisement