Agilent Technologies Acqiris DP105 User Manual

Agilent acqiris 8-bit digitizers
Hide thumbs Also See for Acqiris DP105:
Table of Contents

Advertisement

U
M
SER
ANUAL
A
A
GILENT
CQIRIS
8-
D
BIT
IGITIZERS
For Use with DP and DC Series Digitizers
Models covered:
DP105 / DP106 / DP110 / DP111 / DP210 / DP211 / DP212
DP214 / DP235 / DP240 / DP1400 / DC110 / DC135 / DC140
DC211 / DC211A / / DC241 / DC241A / DC271 / DC271A / DC271AR
DC240 / DC265 / DC270
U1061A / U1063A / U1064A / U1067A / U1068A / U1069A / U1071A
U1091A

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies Acqiris DP105

  • Page 1 For Use with DP and DC Series Digitizers Models covered: DP105 / DP106 / DP110 / DP111 / DP210 / DP211 / DP212 DP214 / DP235 / DP240 / DP1400 / DC110 / DC135 / DC140 DC211 / DC211A / / DC241 / DC241A / DC271 / DC271A / DC271AR...
  • Page 2 The information in this document is subject to change without notice and may not be construed in any way as a commitment by Agilent Technologies, Inc. While Agilent makes every effort to ensure the accuracy and contents of the document it assumes no responsibility for any errors that may appear.
  • Page 3: Table Of Contents

    CONTENTS OUT OF THE BOX... 6 1.1. Message to the User ... 6 1.2. Using this Manual ... 6 1.3. Conventions Used in This Manual ... 6 1.4. Model Names ... 7 1.5. Disclaimer and Safety ... 7 1.6. Warning Regarding Medical Use ... 7 1.7.
  • Page 4 3.3.7. Combining channels... 26 3.4. Trigger... 26 3.4.1. Trigger Source... 26 3.4.2. Trigger Coupling... 27 3.4.3. Trigger Level... 27 3.4.4. Edge Trigger Slope... 27 3.4.5. Window Trigger ... 27 3.4.6. HF Trigger... 27 3.4.7. Spike Stretcher ... 27 3.4.8. U1071A-FAMILY Multi-source Trigger ... 27 3.4.9.
  • Page 5 APPENDIX A: U1093A (U1056A) AS BUS FOR COMPACTPCI/PXI DIGITIZERS ... 49 APPENDIX B: U1093A-AS6 (U1056A-A06) AS BUS 2 FOR PCI DIGITIZERS ... 50 APPENDIX C: -BB1 BATTERY BACKUP FOR COMPACTPCI DIGITIZERS ... 51 APPENDIX D: U1092A-HVB XA100 BNC INPUT OVERVOLTAGE PROTECTION ... 53 10.
  • Page 6: Out Of The Box

    1.1. Message to the User Congratulations on having purchased an Agilent Technologies Acqiris data conversion product. Acqiris digitizers are high-speed data acquisition modules designed for capturing high frequency electronic signals. To get the most out of the products we recommend that you read this manual carefully. We trust the product you have purchased will meet with your expectations and provide you with a high quality solution to your data conversion applications.
  • Page 7: Model Names

    Model Names Agilent Technologies Inc. acquired Acqiris SA and its product lines in December 2006. Use the tables below to cross reference new Agilent numbers with options to the legacy model name. The legacy model name is what is used in the Acqiris applications and the API.
  • Page 8: Packaging And Handling

    Your Digitizer is shipped with the following components: • A compact disc in an Agilent Technologies paper CD envelope that includes 10 product User Manuals in electronic form (8-bit Digitizers, 10-bit Digitizers, 12-bit Digitizers, Averagers, Analyzers, Signal Analyzers, Streamer Analyzers, Time-to-Digital Converters, 3-, 5-, and 8-slot CompactPCI Crates, and the 21-slot CompactPCI Crate), 1 Programmer’s Guide and 1 Programmer’s Reference Manual,...
  • Page 9: System Requirements

    Before issuing a Service Order the service center may ask you to communicate with us by phone or eMail so that we can learn as much as needed about the problems observed. If a unit returned under guarantee is found to be working normally and this procedure was not followed we reserve the right to charge you for the work done.
  • Page 10: Maintenance

    3. After wrapping it with packing material, place the instrument in its original shipping container or a strong shipping container that is made of double-walled corrugated cardboard with 159 kg (350 lb) bursting strength. 4. Seal the shipping container securely with strong nylon adhesive tape.
  • Page 11: Installation

    Installation This chapter describes how to install the Acqiris hardware and software for Windows 2000/XP, National Instruments LabVIEW RT, Linux, or Wind River VxWorks. For a first time installation we strongly recommend installing the software before inserting the NOTE: hardware into the PC. 2.1.
  • Page 12: Installing The Software Under Windows

    The PCI-8570/PXI-8570 User's Manual (Rev. 1.00) section 2.4 contains the software installation instructions. These should be executed before allowing the hardware installation process to look for the driver. If you have an AdLink CD Version 2004A4 or later you can use it; if not you should download the latest driver from the WEB site (http://www.adlinktech.com/).
  • Page 13: Installing The Software For Linux

    If MATLAB is installed on your machine, you will be asked to point the installer to the MATLAB root directory. You should do this if you want the installer to modify the standard startup.m file to add the paths for the MEX interface. In the Installation Folder window you will give the name of the root directory of the Acqiris software installation.
  • Page 14: Installing The Linux Device Driver

    CentOS, 4.7, 5.2 - this distribution is a rebranded build of RedHat Enterprise Linux. CentOS-4.7/agilent-acqirisdriver-3.3a-1.i386.rpm CentOS-5.2/agilent-acqirisdriver-3.3a-1.i386.rpm openSUSE, 11 - this distribution is the base system for Novell SUSE Linux. openSUSE-11/agilent-acqirisdriver-3.3a-1.i586.rpm More information on these distributions is available on the following web-site: http://distrowatch.com/dwres.php?resource=major All these packages contain a version of the software Acqiris 3.3a release for Linux with full support of recent Acqiris products.
  • Page 15: Loading The Kernel Module

    modules (such as this one). As such, automatic creation of the /dev/acqrsPCI node has to be done manually in the /etc/rc.local file (see Creating the device driver node in 2.3.4 Loading the kernel module). 2.3.4. Loading the kernel module Once the device driver is installed into its kernel module directory, it has to be loaded into the kernel. First update the kernel modules dependencies: /sbin/depmod -a Then load the kernel module:...
  • Page 16: Installing The Hardware

    setenv AcqirisDxDir /usr/local/AcqirisLinux/demo or, if your shell is bash, ksh, zsh or sh, modify the .profile file to contain the lines AcqirisDxDir=/usr/local/AcqirisLinux/demo export AcqirisDxDir 2.4. Installing the Hardware 1. Turn off the power of the PC and the crate in the case of a CompactPCI module. CAUTION: For PCI modules the PC may have to be unplugged to ensure that the PCI bus has no power available.
  • Page 17: Windows Xp

    NOTE: In some systems an application program (such as AcqirisLive) will not yet work correctly at this point. One additional boot cycle may be needed if this is the first time that a hardware board is being installed. 2.5.2. Windows XP Under Windows XP, you must login with administrator privileges after the first boot following the hardware installation;...
  • Page 18: Installing The Ivi-Com/C Driver

    Restart the MAX Explorer and you should have Acqiris digitizers detected in your PXI system. 2.7. Installing the IVI-COM/C Driver Please install Acqiris software for Windows first. Then the Acqiris Software CD Autorun program gives access to two installers: IVI Shared Components 1.4 IVI-COM/C IviAqD1 driver These must be installed in the order shown above.
  • Page 19: Product Description

    Product Description 3.1. Overview Signal Input Input Signal Amplifier Ohms Ohms trigger Input Trigger Signal Amplifier Ohms Ohms Acqiris digitizers are available in two popular industry standards. The DP series digitizers are PCI modules that plug directly into a vacant PCI slot in a PC. The PCI Bus is a well-defined industry standard. The DC series products are CompactPCI/PXI compliant and require an appropriate CompactPCI crate.
  • Page 20: Channel Input

    3.2. Channel Input 3.2.1. Coupling Both AC and DC coupling modes are available. The AC mode couples signals capacitively thus removing the input signal’s DC component and filtering out any signal component below 16 Hz for the DC2x1A digitizers, 32 Hz for the DC271-FAMILY and 10 Hz for all other models.
  • Page 21 Bandwidth Bandwidth/ Model into 50 Ω Capacitance Agilent # into 1 MΩ 150 MHz 150 MHz DP105 8 pF U1067A 250 MHz DP106 250 MHz 250 MHz DP110 8 pF U1067A 500 MHz DP111 500 MHz 400 MHz DP210 8 pF...
  • Page 22 Bandwidth Bandwidth/ Model into 50 Ω Capacitance Agilent # into 1 MΩ 500 MHz U1091AD28 250 MHz 250 MHz DC110 U1091A 8 pF 500 MHz DC135 U1061A -001-F50 500 MHz 300 MHz DC135HZ typical U1061A -001-FHZ 18 pF 1 GHz DC140 U1061A -002-F50...
  • Page 23: Input Voltage And Offset

    Model Max. Max. Sampling CONVER Rate TERS PER CHANNEL/ CHANNELS 500 MS/s 1 / 1 DP105 500 MS/s 1 / 1 DP106 1 GS/s 1 / 1 DP110 1 GS/s 1 / 1 DP111 User Manual: Agilent Acqiris 8-bit Digitizers –Offset Voltage + (FS/2)
  • Page 24: Sampling Rate

    Model Max. Max. Sampling CONVER Rate TERS PER CHANNEL/ CHANNELS 2 GS/s 1 / 1 DP210 2 GS/s 1 / 1* DP211 2 GS/s 1 / 1 DP212 2 GS/s 1 / 1 DP214 1 GS/s 2 / 2 DP235 2 GS/s 2 / 2 DP240...
  • Page 25: Acquisition Memory

    3.3.2. Acquisition Memory Data from the ADC is stored in on-board acquisition memory. The amount of memory in use for acquisition can be programmed and is selectable from 1 point to the full amount of acquisition memory available. For technical reasons, a certain memory “overhead” is required for each waveform, reducing the available memory by a small amount.
  • Page 26: Timing

    when the AS bus is present. The number of segments (Ns) available per bank (Nb) must respect the constraint that the total Nb * Ns < 1000. 3.3.5. Timing A crystal-controlled timebase is used to clock the ADC system of the digitizers. The timebase accuracy is guaranteed as shown in the table at the beginning of this section.
  • Page 27: Trigger Coupling

    The U1071A-FAMILY also gives the choice of 50 Ω or 1 MΩ termination impedance for the MCX external input and has diode protection against overload. However, there are no BW limiters and only DC trigger coupling is available. In all 50 Ω cases a ±5 V limit on trigger signals should be respected, although somewhat higher voltages for short time periods will not damage the unit.
  • Page 28: Pre- And Post-Trigger Delay

    These states can be logically combined with AND, OR, NAND, or NOR to define the overall trigger condition. Potential triggers can then occur on the FALSE to TRUE transitions of the combined signal. There is a small (~ns) delay between the times at which two simultaneous inputs arrive at the logical element that defines the overall trigger condition.
  • Page 29: Internal Calibration

    The U1071A-FAMILY has a fixed threshold and uses AC coupling. Otherwise, the transitions of the clock are defined with the aid of a threshold that is user selectable in the range [-2.0 V, 2.0 V] ([-3.0 V, 3.0 V] for the DC240). The signals should not exceed ±5 V amplitude.
  • Page 30: Special Front Panel Input And Output (U1071A-Family & Dc271-Family)

    3.8. Special Front Panel Input and Output (U1071A-FAMILY & DC271- FAMILY) Connector Function CLK IN 50 Ω External Reference or External Clock Input I/O A User configurable (see below) TR OUT Signal occurs after an accepted TRIGGER. I/O B User configurable (see below) The DC271-FAMILY uses MMCX connectors for these functions;...
  • Page 31: Frequency Counter Mode

    The user gate signal has to be made available on one of the Control I/O inputs. 3.11. Electrical, Environmental and Physical Specifications 3.11.1. Electrical Model Transfer Rate (MB/s) ~100 DP105 DP106 ~100 DP110 ~100 DP111 ~100 DP210 ~100...
  • Page 32: Environmental And Physical

    ~100 DC271 DC271A DC271AR The Maximum Power Consumption has been increased by 10% over the value calculated with the currents shown to take into account higher allowed values of the crate or PCI voltages. The U1071A-FAMILY can use the PCI Bus at frequencies up to 66 MHz. All other 8-bit Acqiris digitizers use the PCI Bus at 33 MHz only.
  • Page 33: Running The Acqirislive Application

    Running the AcqirisLive Application AcqirisLive is an application to control and demonstrate the capabilities of Acqiris digitizers on a single machine. AcqirisMAQS is more advanced application offering many interesting possibilities for the control of acquisition systems in a single or multi-machine environment. Ask your sales representative or Agilent Acqiris Support for more information.
  • Page 34: Control Panel And Functions

    Other controls in the control panel allow you to select the optimal acquisition settings for your particular signal. Each of the other control panel functions will be discussed in detail in the following Control Panel Functions section. Here is a sample result. 4.2.
  • Page 35: Displaying Multiple Traces

    Oscilloscope Mode 4.2.2. Displaying Multiple Traces If multi-channel modules, or several single channel modules, are installed on the PCI bus, multiple waveform displays, one from each installed channel, are overlaid on the display. The current channel is selected by clicking on the channel name within the upper portion of the control panel. The vertical settings of the current channel and the timebase and trigger of the correspondent digitizer are then indicated.
  • Page 36: Numeric Editor

    is positioned over a digit that is below the all 4.2.4. Keyboard shortcuts Two shortcuts have been defined to simplify applying changes of a parameter to a group of channels. When the mouse is over the control of a channel parameter - 's' can be used to set the current value to all channels of all available instruments 'c' can be used to set the current value to all channels of the current instrument.
  • Page 37: Trigger

    the control panel. The input voltage scale is set by one of three possible methods: 1. Clicking on the white numeric display of the voltage scale will show a pop-up list. Select the desired gain setting with the mouse pointer. 2.
  • Page 38: Acquisition Mode

    4.2.7. Acquisition Mode waveforms acquired per second by the digitizer. The use of each of the acquisition modes is described below. In the discussion, a valid trigger indicates a trigger signal meeting the trigger conditions at a time when the digitizer is armed and ready to acquire data.
  • Page 39: Using Digitizers Of Different Models Simultaneously

    4.2.9. Using digitizers of different models simultaneously AcqirisLive features a single timebase (i.e. the set of acquisition parameters pertaining to the time axis of the waveform, such as the sampling rate and the number of samples). It is therefore not possible to specify different timebase settings for different digitizers.
  • Page 40: Top Line Menu Of Acqirislive

    When expanding a waveform to the point where individual data points are seen, it may be desirable to use the “Connect data points” option under the Options menu in AcqirisLive. When this option is selected, larger data points are drawn on the display and a line connects each point. The main display window contains a drop down selector that controls the display type for both the main display and the zoom window.
  • Page 41 2. The Autostore option allows you to store consecutively acquired waveforms from all of the active channels into files. Configuration of Autostore is achieved by selecting the Autostore item under the Store menu. Autostore brings up the dialog box shown here. Three formats are available for stored waveforms, Binary, Raw ADC values, and Amplitude values (in Volts).
  • Page 42: Calibrate

    where the data is located, select the output format and click OK. All binary data files found in the source directory will be converted to the desired format. If you are writing amplitudes with multiple segments, formatting with segments in columns is limited to 200 segments. 4.6.
  • Page 43: Display Features

    row, the first column contains the difference t average value of the t in the left column and the standard deviation of the t The “Show Parameters” option activates a display of pulse parameters for each active channel. Inactive channels will have parameter values of 0.0.
  • Page 44 Acqiris averagers can be operated in Averager Mode or in standard Digitizer Mode. AcqirisLive operates in either mode, but since these are mutually exclusive, only instruments that support the chosen mode are accessible in any given mode. E.g. only averagers are accessible in Averager Mode, while both digitizers and averagers are accessible in Digitizer Mode.
  • Page 45 completed. This thread is put to sleep, and wakes up upon reception of the interrupt from the instrument, or after a 2 seconds timeout. Please note that switching the DMA data transfer mode off precludes the use of acquisition interrupts. The –i switch will therefore be ignored when –n is used.
  • Page 46: Running The Geographic Mapper Application

    Running the Geographic Mapper Application 5.1. Who needs a Geographical Map of Modules The Geographic Mapper application gives the user the possibility of telling the Acqiris driver crucial details of the physical position of modules when this information cannot be deduced directly. It allows the driver to correctly adjust trigger and clock delays between the different modules of an AS bus multi-Instrument and arrange the modules in an intuitive order.
  • Page 47 correspond to your expectations you may have hardware problems (unpowered, broken, or badly cabled crates or modules). The next step is to associate each bus segment with a physical crate. The menu to do this is shown below: Selecting a row will cause all of the LED's of modules in that Bus to be turned on RED. This should make it easy to identify which crate the modules are in.
  • Page 48 The final step is to actuate the Save button so that the final configuration will be memorized and made available to the driver. The Geographic Mapper application will always work with the standard AqGeo.map file. If you need to have several such files corresponding to different configurations it is up to you to either rename the files or transfer them to other directories in an appropriate manner.
  • Page 49: Appendix A: U1093A (U1056A) As Bus For Compactpci/Pxi Digitizers

    Appendix A: U1093A (U1056A) AS bus for CompactPCI/PXI Digitizers Specification and User Instructions for AS1, AS2, AS3, AS4 User Manual: Agilent Acqiris 8-bit Digitizers Page 49 of 59...
  • Page 50: Appendix B: U1093A-As6 (U1056A-A06) As Bus 2 For Pci Digitizers

    Appendix B: U1093A-AS6 (U1056A-A06) AS bus 2 for PCI Digitizers User Manual: Agilent Acqiris 8-bit Digitizers Page 50 of 59...
  • Page 51: Appendix C: -Bb1 Battery Backup For Compactpci Digitizers

    Appendix C: -BB1 Battery Backup for CompactPCI Digitizers Specification and Assembly Instructions -BB1 Option User Manual: Agilent Acqiris 8-bit Digitizers Page 51 of 59...
  • Page 52 User Manual: Agilent Acqiris 8-bit Digitizers Page 52 of 59...
  • Page 53: Appendix D: U1092A-Hvb Xa100 Bnc Input Overvoltage Protection

    Appendix D: U1092A-HVB XA100 BNC Input Overvoltage Protection Specifications and User Instructions User Manual: Agilent Acqiris 8-bit Digitizers Page 53 of 59...
  • Page 54: Appendix E: U1091Ax01 Xp100 Fan Unit For Dp1Xx/Dp2Xx Units

    Appendix E: U1091AX01 XP100 Fan Unit for DP1xx/DP2xx units Specification and Assembly Instructions - XP1 Option User Manual: Agilent Acqiris 8-bit Digitizers Page 54 of 59...
  • Page 55: Appendix F: Xp101 Fan Unit For Dp Digitizers (Obsolete)

    Appendix F: XP101 Fan Unit for DP Digitizers (Obsolete) Specification and Assembly Instructions User Manual: Agilent Acqiris 8-bit Digitizers Page 55 of 59...
  • Page 56: Appendix G: U1091Ax03 Xp103 Fan Unit For The Dpxxx Modules

    Appendix G: U1091AX03 XP103 Fan Unit for the DPxxx Modules Specification and Assembly Instructions - XP3 Option User Manual: Agilent Acqiris 8-bit Digitizers Page 56 of 59...
  • Page 57: Appendix H: U1091Ax05 Xp104 Fan Unit For U1071A-Family

    Appendix H: U1091AX05 XP104 Fan Unit for U1071A-FAMILY User Manual: Agilent Acqiris 8-bit Digitizers Page 57 of 59...
  • Page 58 User Manual: Agilent Acqiris 8-bit Digitizers Page 58 of 59...
  • Page 59: Appendix I: U1071A-Xp5 Xp105 Fan Unit For U1071A-Family

    Appendix I: U1071A-XP5 XP105 Fan Unit for U1071A-FAMILY User Manual: Agilent Acqiris 8-bit Digitizers Page 59 of 59...

Table of Contents