Diagnostics
3.1 Diagnostics via LEDs
3.1.4.2

Terminal Module TM31

Table 3- 43
Meanings of the LEDs on the Terminal Module TM31
LED
Color
READY
-
Green
Orange
Red
Green/
red
Green/
orange
or
Red/
orange
3.1.4.3

Terminal Module TM120

Table 3- 44
Meaning of the LEDs on the Terminal Module TM120
LED
Color
Status
-
Off
Green
Continuous
light
Orange
Continuous
light
READY
Red
Continuous
light
Green/
Flashing
Red
light
0.5 Hz
Flashing
light
2 Hz
Green/
orange
Flashing
or
light
red/
2 Hz
orange
214
Status
OFF
Electronics power supply is missing or outside the
permissible tolerance range.
Continuous
The component is ready for operation and cyclic DRIVE-
light
CLiQ communication is taking place.
Continuous
DRIVE-CLiQ communication is being established.
light
Continuous
At least one fault is present in this component.
light
Note:
The LED is activated regardless of whether the
corresponding messages have been reconfigured.
0.5 Hz
Firmware is being downloaded.
flashing
light
2 Hz
Firmware download is complete. Wait for POWER ON
flashing
light
Flashing
Component recognition via LED is activated (p0154).
light
Note:
Both options depend on the LED status when component
recognition is activated via p0154 = 1.
Description, cause
Electronics power supply is missing or outside permissible
tolerance range.
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
DRIVE-CLiQ communication is being established.
At least one fault is present in this component. Note:
The LED is activated regardless of whether the corresponding
messages have been reconfigured.
Firmware is being downloaded.
Firmware download is complete. Wait for POWER ON
Detection of the components via LED is activated (p0154).
Note:
Both options depend on the LED status when module
recognition is activated via p0154 = 1.
Description, cause
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
Remedy
Remedy and
acknowledge fault
Carry out a POWER
ON
Remedy
Check power supply
-
-
Remedy and
acknowledge fault
-
Carry out a POWER
ON
-