Description Of The Led States Of A Cu 310-2 - Siemens SINAMICS S120 Commissioning Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

LED
Color
Red
OPT
(OPTION)
Green
Red
RDY and DP
Red
RDY and OPT Orange
3.1.1.2

Description of the LED states of a CU 310-2

There are four LEDs on the front panel of the CU310-2 DP's housing (see section:
"Overview", illustration: "CU310-2 DP Interface overview").
Table 3- 8
RDY
COM
OUT>5V
MOD
The various LEDs are switched on and off as the control unit is powered up (depending on
the phase the system is currently running through). When switched on, the color of the LEDs
shows the status of the corresponding power-up phase (see section: "LED display during
power up").
In the event of a fault, power up will be ended in the corresponding phase. The LEDs that
are switched on retain their colors so that the fault can be determined on the basis of the
combination of the color LEDs that are lit and unlit.
All the LEDs go out briefly if the CU310-2 DP has powered up without error. The system is
ready for operation when the LED "RDY" is permanently green.
All the LEDs are controlled by the software loaded during operation (see section: "LED
display during operation").
Commissioning Manual
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
Status
0.5 Hz
Bus error,
flashing
incorrect parameter assignment/configuration
light
2 Hz
Cyclic bus communication has been interrupted
flashing
or could not be established
light
Off
Electronics power supply is missing or outside
the permissible tolerance range.
Component is not ready.
Option board not installed or no associated drive
object has been created.
Continuous
Option board is ready.
light
0.5 Hz
Depends on the option board used.
flashing
light
2 Hz
This component has at least one fault.
flashing
The Option Board is not ready (e.g. after
light
switching on).
2 Hz
Bus error - communication has been interrupted
flashing
light
0.5 Hz
Firmware update in progress for connected
flashing
Option Board CBE20
light
LEDs
Ready
Option Board
Encoder current supply > 5 V (TTL/HTL)
Operating mode (reserved)
Description, cause
Diagnostics
3.1 Diagnostics via LEDs
Remedy
Adapt configuration between
controller and devices
Remove fault
Check power supply and/or
component
Remove the fault and
acknowledge
Remove fault
-
189