Preparation for commissioning
1.5 Rules for wiring with DRIVE-CLiQ
1.5.7

Topology example: Parallel Motor Modules in vector control

Drive line-up with two parallel-connected Line Modules and Motor Modules in the chassis format of
the same type
Parallel-connected Line Modules in the chassis format and Motor Modules in the chassis
format of the same type can be connected to a DRIVE-CLiQ socket of the Control Unit.
In the following diagram, two Active Line Modules and two Motor Modules are connected to
the X100 or X101 socket.
For further information on parallel connection, see the chapter "Parallel connection of power
units" in the SINAMICS S120 Function Manual.
Note
This topology does not match the topology created offline by STARTER and must be
changed manually.
Figure 1-8
44
Drive line-up with parallel-connected power units in the chassis format
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
Commissioning Manual