2.16 Temperature sensors for SINAMICS components
● With p4108[0...5] = 2, you evaluate a sensor in a 3-wire system at a 4-wire connection at
● With p4108[0...5] = 3, you evaluate a sensor in a 4-wire system at a 4-wire connection at
You can find additional information in function diagram 9626 in the SINAMICS S120/S150
List Manual and in the SINAMICS S120 Function Manual in Chapter "Thermal motor
protection".
SME20
The evaluation of KTY or PTC temperature sensors can be parameterized using the
STARTER screen form (Signals and monitoring \ motor temperature):
● Temperature sensor selection (≙ p0600[0..n]): Selection of the source to which the SME
● Temperature sensor type (≙ p0601[0..n]): Sets the sensor type for motor temperature
178
terminals 3 and 4. The measuring cable is connected to terminal 1. You must short-circuit
terminals 2 and 4.
terminals 3 and 4. The measuring cable is connected to terminals 1 and 2.
module is assigned (temperature sensor via encoder (1, 2 or 3), temperature sensor via
BICO interconnections or temperature sensor via Motor Module)
monitoring.
Figure 2-46
Selection of temperature sensor for SME20 modules