Selection And Configuration Of Encoders - Siemens SINAMICS S120 Commissioning Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Commissioning

2.12 Selection and configuration of encoders

2.12
Selection and configuration of encoders
Encoder selection
For a SINAMICS drive system, there are three possibilities of selecting the encoder using
STARTER:
1. Evaluating the motor and encoder data via a DRIVE-CLiQ interface.
2. Select a standard encoder from a list (also possible via the motor order number for
3. Manually entering user-defined encoder data. In this case, the encoder can be configured
The encoders can also be configured on their own using parameters (parameters p0400 to
p0499).
Table 2- 16
Assigning encoder type, encoder code and evaluation modules for standard encoders
Encoder type
DRIVE-CLiQ
Absolute rotary
encoder
value
Resolver
Incremental
rotary
Encoder with
Incremental
sin/cos 1Vpp
encoder
rotary
EnDat
Absolute value
encoder
rotary
SSI encoder
Absolute value
with
rotary
sin/cos 1Vpp
144
The encoder is automatically identified by setting the parameter p0400 = 10000 or 10100,
i.e. all of the motor and encoder data required for the configuration are read out of the
encoder. For p0400 = 10100, the identification time is not limited.
encoder 1/motor encoder). Every encoder type on the list has a code number (see
SINAMICS S120/S150 List Manual), that can also be assigned using parameter p0400
(encoder type selection).
using the encoder-specific input screens in STARTER.
Encoder code Encoder evaluation procedure
202
242
204
244
1001
1002
1003
1004
2001
2002
2003
2005
2010
2051
2052
2053
2054
2055
2081
2082
2083
2084
Abs., singleturn 20 bit
abs., singleturn 24 Bit
abs., multiturn 12 bit, singleturn 20 bit)
abs., multiturn 12 bit, singleturn 24 bit)
Resolver 1-speed
Resolver 2-speed
Resolver 3-speed
Resolver 4-speed
2048, 1 Vpp, A/B C/D R
2048, 1 Vpp, A/B R
256, 1 Vpp, A/B R
512, 1 Vpp, A/B R
18000, 1 Vpp, A/B R distance-coded
2048, 1 Vpp, A/B, EnDat, multiturn 4096
32, 1 Vpp, A/B, EnDat, multiturn 4096
512, 1 Vpp, A/B, EnDat, multiturn 4096
16, 1 Vpp, A/B, EnDat, multiturn 4096
2048, 1 Vpp, A/B, EnDat, singleturn
2048, 1 Vpp, A/B, SSI, singleturn
2048, 1 Vpp, A/B, SSI, multiturn 4096
2048, 1 Vpp, A/B, SSI, singleturn, error bit
2048, 1 Vpp, A/B, SSI, multiturn 4096, error
bit
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
Evaluation module
-
SMC10, SMI10
SMC20, SMI20,
SME20, SME120
SMC20, SMI20,
SME25
SMC20, SMI20,
SME25, SME125
Commissioning Manual

Advertisement

Table of Contents
loading