Siemens SINAMICS S120 Commissioning Manual page 127

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

What to do?
6.2
Enable Motor
Module
6.3
Ramp-function
generator
configuration
Commissioning Manual
Commissioning Manual, (IH1), 01/2012, 6SL3097-4AF00-0BP2
2.7 First commissioning, vector control mode in the chassis format
Enable signals for the Motor Module (drive_1):
p0840 = 722.0 ON/OFF1
p0844 = 722.1 1. OFF2
p0845 = 1 2. OFF2
p0848 = 722.2 1. OFF3
p0849 = 1 2. OFF3
p0852 = 722.3 Enable operation
p0864 = 863.0 Infeed operation
Ramp-function generator
p1140 = 1 Ramp-function generator enable
p1141 = 1 Ramp-function generator start
p1142 = 1 Enable setpoint
How to do it?
Commissioning
Comment
See function diagram
[2501]
See function diagram
[3060]
125

Advertisement

Table of Contents
loading