Europe - Emerson 5301HxxxxxxxxxxxxxxZZ Series Reference Manual

Guided wave radar level transmitter
Table of Contents

Advertisement

Product certifications
April 2019
Standards CSA C22.2 No.0-M91, CSA C22.2 No.25-1966, CSA C22.2 No.30-M1986,
Markings
FISCO parameters
B.7

Europe

B.7.1
E1 ATEX Flameproof
Certificate Nemko 04ATEX1073X
Standards EN 60079-0:2012, EN 60079-1:2014, EN 60079-11:2012, EN
Markings
Special Conditions for Safe Use (X):
1. Potential ignition hazards by impact or friction need to be considered according to
2. Parts of the sensor probes, for type 5300 are non-conducting material covering
3. 1/2" NPT threads need to be sealed for dust and water ingress protection, IP 66, IP
B.7.2
I1 ATEX Intrinsic Safety
Certificate Nemko 04ATEX1073X
Standards EN 60079-0:2012, EN 60079-1:2014, EN 60079-11:2012, EN
Markings
362
CSA C22.2 No.94-M91, CSA C22.2 No.142-M1987, CSA C22.2 157-92,
CAN/CSA C22.2 No. 60529:05, ANSI/ISA 12.27.01-2003
CL I, DIV 1, GP A, B, C, D, T4 see installation drawing 9240030-937; Non-
Incendive Class III, DIV 1, Haz-loc CL I DIV 2, GP A, B, C, D, Maximum
Ambient Temperature +60 °C, T4, Type 4X/IP66/IP67, Maximum Working
Pressure 5000 psi, Dual Seal.
Ui
17.5 V
60079-26:2015, EN 60079-31:2014
II 1/2G Ex db ia IIC T4 Ga/Gb, (-40 °C ≤ Ta ≤ +60 °C /+70 °C)
II 1D Ex ta IIIC T69 °C/T79 °C Da, (-40 °C ≤ Ta ≤ +60 °C /+70 °C)
Um = 250 V
EN 60079-0:2012 clause 8.3 (for EPL Ga and EPG Gb), and clause 8.4 (for EPL Da and
EPL Db), when the transmitter enclosure and antennas exposed to the exterior
atmosphere of the tank, is made with light metals containing aluminium or
titanium. The end user shall determine the suitability with regard to avoid hazards
from impact and friction.
metal surfaces. The area of the non-conducting part exceeds the maximum
permissible areas for Group III according to EN 60079-0.2012 clause 7.4:3.
Therefore, when the probe is used in a potentially explosive atmosphere group III,
EPL Da, appropriate measures must be taken to prevent electrostatic discharge.
67 or "Ex t", EPL Da or Db is required.
60079-26:2015, EN 60079-31:2014
II 1G Ex ia IIC T4 Ga, (-55 °C ≤ Ta ≤ +60 °C/+70 °C)
Ii
Pi
380 mA
5.32 W
Rosemount 5300 Level Transmitter
Reference Manual
00809-0100-4530
Ci
Li
0
0

Hide quick links:

Advertisement

Table of Contents
loading