Application Examples - Emerson 5301HxxxxxxxxxxxxxxZZ Series Reference Manual

Guided wave radar level transmitter
Table of Contents

Advertisement

Transmitter overview
April 2019
2.2

Application examples

The Rosemount 5300 Level Transmitter series is suited for aggregate (total) level
measurements on most liquids, semi-liquids, solids, and liquid/liquid interfaces.
Guided microwave technology offers the highest reliability and precision to ensure
measurements are virtually unaffected by temperature, pressure, vapor gas mixtures,
density, turbulence, bubbling/boiling, low level, varying dielectric media, pH, and
viscosity.
Guided wave radar technology in combination with advanced signal processing makes the
Rosemount 5300 Level Transmitters suitable for a wide range of applications:
Boiling conditions with vapor and turbulence
The Rosemount 5300 Level Transmitter works well in boiling conditions with vapor and
turbulence. If there are disturbing objects in the vicinity of the transmitter, the coaxial
probe is particularly suitable.
Separators, accumulators, and production tanks
The Rosemount 5302 measures both level and interface level in a separator tank.
Chamber applications
The Rosemount 5300 Level Transmitter is well suited for chamber applications, such as
distillation columns.
12
5301
5302
Oil
Water
Oil
Reference Manual
00809-0100-4530
Rosemount 5300 Level Transmitter

Hide quick links: