Europe; E1 Atex Flameproof; B.10 Europe - Emerson Rosemount 5408 Reference Manual

Level transmitters non-contacting radar
Hide thumbs Also See for Rosemount 5408:
Table of Contents

Advertisement

Table B-7:
Temperature class / Maximum
surface temperature
Division Gas groups:
T2
T3
T4
Division Dust groups:
T3
T4
T5
T6
Table B-8:
Temperature class / Maximum
surface temperature
Zone Gas groups:
T2
T3
T4
Zone Dust groups:
T250°C
T200°C
T135°C
T100°C
T85°C
B.10

Europe

B.10.1

E1 ATEX Flameproof

Certificate: FM15ATEX0055X
Standards: EN 60079-0:2012, EN 60079-1:2014, EN 60079-26:2015, EN
Markings:
Rosemount 5408 and 5408:SIS Level Transmitters
For Divisions:
Ambient temperature range Process temperature range
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
For Zones:
Ambient temperature range Process temperature range
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
-60°C ≤ Ta ≤ 70°C
60079-31:2014, EN 60529+A1+A2:2013
II 1/2G Ex db IIC T6...T2 Ga/Gb
II 2D Ex tb IIIC T85°C... T250°C Db, IP6X
(-60°C ≤ Ta ≤ +70 °C)
Product Certifications
-60°C to 250°C
-60°C to 195°C
-60°C to 130°C
-60°C to 160°C
-60°C to 130°C
-60°C to 95°C
-60°C to 80°C
-60°C to 250°C
-60°C to 195°C
-60°C to 130°C
-60°C to 250°C
-60°C to 195°C
-60°C to 130°C
-60°C to 95°C
-60°C to 80°C
203

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rosemount 5408:sis

Table of Contents