5. Secure the split pins.
3.5

Mount device on tank

Mount the transmitter with flange on a nozzle on top of the tank. The transmitter can also
be mounted on a threaded or Tri-Clamp
3.5.1
Tank connection with flange
Prerequisites
Note
PTFE covered probes must be handled carefully to prevent damage to the coating.
Procedure
1. Place a suitable gasket on top of the tank flange.
Reference Manual
Note
Gasket should not be used for PTFE covered probe with protective plate.
®
connection.
Mechanical installation
April 2019