Optional Devices - Emerson 5301HxxxxxxxxxxxxxxZZ Series Reference Manual

Guided wave radar level transmitter
Table of Contents

Advertisement

Electrical installation
April 2019
11. Connect the power supply.
4.10

Optional devices

4.10.1
Rosemount
The Rosemount 5300 Level Transmitter outputs a HART signal with four process variables.
By using the Rosemount 333 HART Tri-Loop, up to three additional analog 4-20 mA
outputs are provided.
Each Tri-Loop channel receives power from control room. Channel 1 must be powered for
the Tri-Loop to operate.
Rosemount 5300 recieves power from control room.
Figure 4-16: Example Installation of Rosemount 333 with Rosemount 5300
A. Approved IS barrier
B. DIN rail mounted Rosemount 333
C. Load resistance (≥250 Ω)
D. Control room
110
®
333 HART
Tri-Loop
Reference Manual
00809-0100-4530
Rosemount 5300 Level Transmitter

Hide quick links: