Canada; Europe - Emerson Rosemount 3051S Series Reference Manual

Pressure transmitter with foundation fieldbus protocol
Hide thumbs Also See for Rosemount 3051S Series:
Table of Contents

Advertisement

Reference Manual
00809-0200-4801, Rev DA
IE
FM FISCO
Certificate: 3012350
Standards: FM Class 3600 – 2011, FM Class 3610 – 2010, FM
Class 3611 – 2004, FM Class 3810 – 2005, NEMA
250 – 2003
Markings: IS CL I, DIV 1, GP A, B, C, D; T4(–50 °C
when connected per Rosemount drawing
03151-1006; Type 4X
Special Condition for Safe Use:
1. The Rosemount 3051S/3051S-ERS Pressure Transmitter
contains aluminum and is considered to constitute a
potential risk of ignition by impact or friction. Care must be
taken into account during installation and use to prevent
impact and friction.
B.5 Canada
E6
CSA Explosionproof, Dust-Ignitionproof, and Division 2
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
25-1966, CSA Std C22.2 No. 30-M1986, CAN/CSA
C22.2 No. 94-M91, CSA Std C22.2 No.
142-M1987, CSA Std C22.2 No. 213-M1987,
ANSI/ISA 12.27.01-2003, CSA Std C22.2 No.
60529:05
Markings: Explosionproof Class I, Division 1, Groups B, C, D;
Dust-Ignitionproof Class II, Division 1, Groups E, F,
G; Class III; suitable for Class I, Zone 1, Group
IIB+H2, T5; suitable for Class I, Division 2, Groups A,
B, C, D; suitable for Class I, Zone 2, Group IIC, T5;
when connected per Rosemount drawing
03151-1013; Type 4X
I6
CSA Intrinsically Safe
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
30-M1986, CAN/CSA C22.2 No. 94-M91, CSA Std
C22.2 No. 142-M1987, CSA Std C22.2 No. 157-92,
ANSI/ISA 12.27.01-2003, CSA Std C22.2 No.
60529:05
Markings: Intrinsically Safe Class I, Division 1; Groups A, B, C,
D; suitable for Class 1, Zone 0, IIC, T3C; when
connected per Rosemount drawing 03151-1016
[3051S] 03151-1313 [ERS]; Type 4X
IF
CSA FISCO
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No.
30-M1986, CAN/CSA C22.2 No. 94-M91, CSA Std
C22.2 No. 142-M1987, CSA Std C22.2 No. 157-92,
ANSI/ISA 12.27.01-2003, CSA Std C22.2 No.
60529:05
160
Markings: FISCO Intrinsically Safe Class I, Division 1; Groups
B.6 Europe
T
+60 °C);
a
E1
ATEX Flameproof
Certificate: KEMA 00ATEX2143X
Standards: EN 60079-0:2012, EN 60079-1:2007, EN
Markings:
Temperature class
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm. Installation,
maintenance and use shall take into account the
environmental conditions to which the diaphragm will be
subjected. The manufacturer's instructions for installation
and maintenance shall be followed in detail to assure safety
during its expected lifetime.
2. For information on the dimensions of the flameproof joints,
the manufacturer shall be contacted.
I1
ATEX Intrinsic Safety
Certificate: BAS01ATEX1303X
Standards: EN 60079-0:2012, EN 60079-11:2012
Markings:
Model
SuperModule
3051S...A; 3051SF...A;
3051SAL...C
3051S...F; 3051SF...F
3051S ...A...M7, M8, or M9;
3051SF ...A...M7, M8, or M9;
3051SAL...C... M7, M8, or M9
3051SAL or 3051SAM
3051SAL...M7, M8, or M9
3051SAM...M7, M8, or M9
RTD Option for 3051SF
Product Certifications
A, B, C, D; suitable for Class 1, Zone 0, IIC, T3C;
when connected per Rosemount drawing
03151-1016 [3051S] 03151-1313 [ERS]; Type 4X
60079-26:2007 (3051SFx models with RTD are
certified to EN60079-0:2006)
II 1/2 G Ex d IIC T6...T4 Ga/Gb, T6(–60 °C
+70 °C), T5/T4(–60 °C
T
a
Process temperature
T6
–60 °C to +70 °C
T5
–60 °C to +80 °C
T4
–60 °C to +120 °C
II 1 G Ex ia IIC T4 Ga, T4(–60 °C
U
I
i
30 V
300 mA
30 V
300 m
30 V
300 mA
30 V
300 mA
30 V
300 mA
30 V
300 mA
5 V
500 mA
October 2016
T
a
+80 °C)
T
+70 °C)
a
P
C
L
i
i
i
1.0 W
30 nF
0
A
1.0 W
12 nF
0
i
1.3 W
0
0
60 H
1.0 W
12 nF
33 H
1.0 W
12 nF
93 H
1.0 W
12 nF
0.63 W
N/A
N/A
Product Certifications