Restoring the default settings using the DIL switch
1. The power supply is shut down.
2. Select the MRES operating mode by
3. Restart the power supply.
4. Change to the required mode by setting the DIL switch.
5.17

System shutdown

All axes and system components must be in safe state before you shut down the system. You
can set up this safe state by providing a separate motion task, for example.
You can shut down the power supply after the system has reached a standstill state.
Note
You must observe the safety notices for SINAMICS components, which you can find in the
corresponding SINAMICS manuals.
SIMOTION D410
Commissioning Manual, 04/2014
– Setting mode selector switches S1 to S3 to OFF AND
– Using the service selector switches to ensure that no service functions are selected (S4
to S7 = OFF).
(See figure below.)
Figure 5-42
MRES switch position
The SIMOTION user data is deleted. The default settings are loaded. SIMOTION D410
remains in STOP mode.
Note
The default communications parameters are now restored. You must re-configure the
communication parameters of SIMOTION D410.
Commissioning (software)
5.17 System shutdown