Axis test
1. Open the "AXES" folder in the Project Navigator and click the "Control panel" entry below
Figure 5-23
Axis control panel
2. To display the control range and axis diagnostics, click the "Show/hide control range" and
3. Click "Assume control priority".
SIMOTION D410
Commissioning Manual, 04/2014
the axis (for example, Axis_1).
The axis control panel is displayed.
"Show/hide diagnostics area" buttons.
If the CPU is in RUN mode, confirm the notice that appears with "Yes" to set the controller
to STOPU mode.
Note
In order to move the axis from the PG/PC, you must assume control priority. However, by
pressing the SPACER bar, you can stop the axis at any time.
Commissioning (software)
5.6 Creating and testing an axis
119