Siemens SIMOTION D410 Commissioning Manual page 216

Hide thumbs Also See for SIMOTION D410:
Table of Contents

Advertisement

Configuring drive-related I/Os (without symbolic assignment)
A.2 Local and global measuring inputs
Table A-1
Comparison of local and global measuring inputs
Hardware supported
Measurement procedure
Configuration of the TO
measuringInput in SIMOTION SCOUT
Measuring input TO setting: Single
measurement
1)
Measuring input TO setting: Cyclic
measurement
2)
Use of multiple measuring input TOs
on one axis/encoder. They can be
active concurrently
Listening TO measuringInput
Measuring on virtual axes
Measuring on axes attached to a
different drive unit
Measurement jobs must be issued individually for each measurement. Several interpolation cycle clocks lie between two
1)
measurements.
The measuring is activated just once and runs cyclically until deactivated
2)
SIMOTION Utilities & Applications includes, for example, a tool with the following functions:
● Estimate of the time between initiating a measurement job to the time at which the
● Estimate of the minimum time between 2 measurement jobs
216
Local measuring input
D410, D410-2, D4x5, D4x5‑2
(terminal X122/X132), CX32,
CX32‑2, CU310, CU310-2, CU320,
CU320‑2
With a signal edge at the relevant
input, the current actual values of
an encoder connected to a control
unit are measured with positioning
accuracy to determine lengths and
distances.
The assignment of inputs is always
permanent depending on the
hardware of the control unit and is
performed during the configuration
of the measuring input TO using the
measuring input number.
Yes
No
No
No
No
No
measuring input job in the drive acts
Global measuring input
TM15, TM17 High Feature, D410, D410-2,
D4x5, D4x5‑2 (terminal X122, X132, X142),
CX32, CX32‑2, CU310, CU310-2, CU320,
CU320‑2
With a signal edge at the relevant input, the
current actual values of one or more encoders
are measured using time stamp functionality
with positioning accuracy in order to provide
information for determining lengths and
distances (possible with any encoders
included in the project).
The assignment of inputs is not fixed
depending on the hardware and is performed
during the configuration of the TO
measuringInput by means of symbolic
assignment or the hardware address.
Yes
Yes
D410, D410-2, D4x5, D4x5‑2 (terminal X122,
X132), CX32, CX32‑2, CU310, CU310-2,
CU320, CU320‑2:
The minimum interval between two
measurements is 3 position control cycle
clocks (max. 2 edges per measurement).
D4x5‑2 (terminal X142), TM17 High Feature:
The minimum interval between two
measurements is 1 position control cycle clock
(max. 2 edges per measurement).
TM15:
No cyclic measurement available
Yes
Yes
Yes
Yes
Commissioning Manual, 04/2014
SIMOTION D410