Configuring drive-related I/Os (without symbolic assignment)
A.3 Configuring local measuring inputs
Parameters in the expert list of the drive
p0488[2]
(measuring input 1 input terminal, encoder 3)
p0489[0]
(measuring input 2 input terminal, encoder 1)
p0489[1]
(measuring input 2 input terminal, encoder 2)
p0489[2]
(measuring input 2 input terminal, encoder 3)
Since a maximum of three encoders can be assigned to a drive, the index [0...2] specifies
whether the measurement applies to encoder 1, 2, or 3.
The following must be taken into account:
● Two Measuring Input TOs can be configured per Axis TO or External Encoder TO.
● Only one Measuring Input TO can be active on an Axis TO or External Encoder TO.
Table A-4
Axis measuring
system no.
Drive-related (local
measuring input)
Measuring input
number
Detailed information can be found in the
Measuring Inputs Function Manual.
218
Local measuring inputs, configuration of the Measuring Input TO
Under axis measuring system number, enter the number of the used encoder
system (namely, encoder 1, 2 or 3). Encoder system 1 is the default setting.
Activate the checkbox when a local measuring input is used.
Enter here which measuring input is used (namely, 1 or 2). Input 1 is the
default setting.
Parameterization as
D410, CU310
SIMOTION Motion Control Output Cams and
CU320
DI/DO 14 or
DI/DO 15
SIMOTION D410
Commissioning Manual, 04/2014