Table 6- 61
Default output process image (master to slave) - Single slave mode
Bit
Usage
DO0
Motor control bit 0
DO1
Motor control bit 1
DO2
Motor control bit 2
DO3
Motor contr0l bit 3
(1) The AS-i specification mandates the simultaneous use of 'Motor Left' and 'Motor Right' as fault acknowledge, particu-
larly if there is no spare input available for this function.
(2) If no fault is active then simultaneous operation of 'Motor Left' and 'Motor Right' constitutes a process image error. In
this state both the inverter motor outputs and the motor holding brake outputs are inactive, causing the motor to coast to a
halt and engaging the motor holding brake in exactly the same way as an OFF2 command. This state is maintained until
both 'Motor Left' and 'Motor Right' are deactivated at the same time.
PKW mechanism for parameter transfer
A single message type is used which contains the parameter number to be read or written.
The structure of the message is based on the PKW protocol as used in USS
communications.
Structure
The basic structure of the PKW is shown in the figure below. it consists of two words of
metadata followed by parameter data s required. As required by AS-i, all transfers are
initiated by the AS-i master and where appropriate, responded to by the slave.
Image 6-34
SINAMICS G110D
Operating Instructions, 07/2016, FW V3.63, A5E36768472B AB
Description
DO3 DO2 DO1 DO0
0
0
0
0
0
0
0
1
0
0
1
0
0
0
1
1
0
1
0
0
0
1
0
1
0
1
1
0
0
1
1
1
1
0
0
0
1
0
0
1
1
0
1
0
1
0
1
1
1
1
0
0
1
1
0
1
1
1
1
0
1
1
1
1
With no trip: OFF2 (2)
PKW component structure
6.11 Operation in fieldbus systems
OFF1
Fixed frequency 1
Fixed frequency 2
Fixed frequency 3
Fixed frequency 4
Fixed frequency 5
Fixed frequency 6
Fixed frequency 7
Fixed frequency 8
Fixed frequency 9
Fixed frequency 10
Fixed frequency 11
Fixed frequency 12
Fixed frequency 13
Fixed frequency 14
With active trip: Fault acknowledge (1)
Functions
(default 50 Hz)
(default -50 Hz)
(default 10 Hz)
(default 15 Hz)
(default 20 Hz)
(default 25 Hz)
(default 30 Hz)
(default 35 Hz)
(default 40 Hz)
(default 45 Hz)
(default 50 Hz)
(default 55 Hz)
(default 60 Hz)
(default 65 Hz)
175

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents