Siemens SINAMICS G110D Operating Instructions Manual page 147

Distributed converter
Hide thumbs Also See for SINAMICS G110D:
Table of Contents

Advertisement

Input values
Table 6- 45
Parameter Description
P1200 =
...
Table 6- 46
P1200
0
1
2
3
4
5
6
Table 6- 47
Parameter Description
P1202 =
...
P1203 =
...
SINAMICS G110D
Operating Instructions, 07/2016, FW V3.63, A5E36768472B AB
Main function parameters
Flying restart
0: locked (factory setting),
1 - 6 Active
Overview: the "flying restart" function
Flying restart active
Flying restart locked (factory setting)
Flying restart always active
Flying restart active after:
Power ON
Faults
OFF2
Flying restart active after
Faults
OFF2
Flying restart always active
Flying restart is active after
Power ON
Faults
OFF2
Flying restart is active after
Faults
OFF2
Additional commissioning parameters
Motor current: Flying restart
(entered in %): 10 % ... 200 %, factory setting 100 %
Defines the search current with respect to the rated motor current (P0305) that is pre-
sent when the "flying restart" function is used.
Search rate/speed: Flying restart
(entered in %): 10 % ... 200 %, factory setting 100 %
Sets the factor by which the output frequency changes during the flying restart to syn-
chronize itself with the running motor.
6.9 Technological functions
Search direction
-
Search performed in both directions, startup in
direction of setpoint
Search performed in both directions, startup in
direction of setpoint
Search performed in both directions, startup in
direction of setpoint
Search performed in direction of setpoint only
Search performed in direction of setpoint only
Search performed in direction of setpoint only
Functions
147

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents