Testing and running | Skipping NC blocks
6.6

Skipping NC blocks

You can have NC blocks skipped in the following operating modes:
Test Run
Program run, full sequence
Program run, single block
Positioning w/ Manual Data Input
Operating notes:
This function does not work for TOOL DEF blocks.
After a power interruption the control returns to the
most recently selected setting.
The setting of the HIDE soft key is only effective in
the respective operating mode.
Test Run and Program Run
Application
In Test Run or Program Run, Full Sequence/Single Block
operating mode, the control can skip over NC blocks that you have
prefaced with a slash (/):
Set the HIDE soft key to ON
The control skips the NC blocks.
Set the HIDE soft key to OFF
The control runs or tests the NC blocks.
Procedure
You can optionally hide NC blocks.
Proceed as follows to hide NC blocks in the Programming operat-
ing mode:
Select the desired NC block
Press the INSERT soft key
The control inserts a slash (/).
Proceed as follows to show NC blocks in the Programming
operating mode again:
Select the hidden NC block
Press the REMOVE soft key
The control removes the slash (/).
HEIDENHAIN | TNC 620 | User's Manual for Setup, Testing and Running NC Programs | 10/2018