5

Selecting the probing cycle

Select the Manual operation or Electronic handwheel mode of
operation
Select the probing functions: Press the
TOUCH PROBE soft key
Select the touch probe cycle by pressing the
appropriate soft key, for example PROBING POS
The control displays the associated menu.
Operating notes:
When you select a manual probing function, the
control opens a form displaying all data required.
The content of the forms varies depending on the
respective function.
You can also enter values in some of the fields. Use
the arrow keys to switch to the desired input field.
You can position the cursor only in fields that can be
edited. Fields that cannot be edited are dimmed.
Recording measured values from the touch probe
cycles
Refer to your machine manual.
The control must be specially prepared by the machine
tool builder for use of this function.
After executing the respective touch-probe cycle, the control writes
the measured values to the TCHPRMAN.html file.
If you have not defined a path in the machine parameter
FN16DefaultPath (no. 102202), the control will store the
TCHPRMAN.html file in the TNC:\ main directory.
Operating notes:
If you run several touch probes cycles in a row, the
control stores the measured values below each
other.