HEROS functions | Window manager
Configuring the control
Adjusting the firewall settings:
The State Reporting Interface uses TCP Port 19090 to transfer
the acquired operating states.
Accesses to the SRI from the company network (X26 connection)
must be permitted in the firewall settings.
Allow SRI
Further information:
"Firewall", Page 383
If the SRI is accessed locally via an IPC connected to
the machine network (X116), eth0 (X26) can also remain
locked.
Activating the State Reporting Interface:
In the control's factory default setting, the SRI is deactivated.
Press the DIADUR key to open the HEROS menu
Select the Settings menu item
Select the State Reporting Interface menu item
Activate the State Reporting Interface in the SRI pop-up
window
Further information:
"Overview of taskbar", Page 365
To clear all previous operating states, use the
Clear historical data button.