Engine
Fuel system
10.
2. Detecting and cancelling faults
Detecting faults
This is carried out during the basic functions through which the sensor/actuator is managed.
Memorizing the error and the structure of the errors memory
The errors are memorized in the control unit in the order in which they occur.
The following is memorized for each of them:
- the error code (component and type of error),
- the error counter,
- the time elapsed since the error was detected,
- two environmental conditions (specific for each type of fault) at the time the fault was detected.
Classification of the fault
If a fault is recognized for the first time and the error state persists for a certain length of time, the fault is
memorized as "permanent". If this fault later disappears, then it is memorized as "not present". The
classification of a fault as "permanent" activates the recovery functions: when the fault disappears, nor-
mal operation is restored.
The presence of a "permanent" fault also involves the system failure warning light in the dashboard
coming on.
Frequency counter
The counter, which goes from 0 to 127 and which is activated in the case of a fault, is decreased each
time the engine is started up without the fault reappearing: when the counter reaches zero, the fault is
automatically cancelled from the memory.
Failure warning light
The failure warning light comes on when there is at least on "permanent" fault in the memory.
NOTE
During starting, the warning light is:
- on for 4 seconds,
- off for 0.15 seconds,
- kept on/off according to whether or not there are "permanent" errors.
Cancelling of the errors
When the frequency counter reaches zero, the fault and the parameters associated with it are cancelled.
The immediate cancelling of the entire errors memory takes place in the following cases:
- through the "cancel errors memory" command sent by the F / L Tester;
- by interrupting the electrical supply for the control unit (disconnecting the battery or the control unit
connectors) for at least 60 seconds.
3. Activating the actuators (active diagnosis)
The following actuators are activated with the engine switched off via a command from the F / L Tester:
- injectors (in the order cyls. 1, 2, 3 and 4 ) ,
- coils (in the order cyls. 1, 2, 3 and 4 ) ,
- electric fuel pump relay,
- charcoal filter solenoid valve,
- engine idle adjustment solenoid valve,
- system failure light,
- rev counter signal,
18
Bravo-Brava
- climate control compressor relay (if fitted),
- electric fan low speed relay,
- electric fan high speed relay (if fitted).