GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
Port. Specify the port on the host to which syslog messages are sent. The default
port is 514.
Severity Filter. Select the severity of the logs to send to the logging host. Logs with
the selected severity level and all logs of greater severity are sent to the host. For
example, if you select Error, the logged messages include Error, Critical, Alert, and
Emergency. The default severity level is Alert (1). The severity can be one of the
following levels:
Emergency (0)
functioning properly, an emergency log is saved to the device.
Alert (1)
The second-highest warning level. An alert log is saved if there is a
.
serious device malfunction, such as all device features being down.
Critical (2)
device malfunction occurs, for example, two device ports are not functioning,
while the rest of the device ports remain functional.
Error (3)
A device error has occurred, such as if a port is offline.
.
Warning (4)
Notice (5)
.
Informational (6)
Debug (7)
.
performed by qualified support personnel.
The Status field in the Server Log table shows whether the remote logging host is active.
Use the buttons at the bottom of the screen to perform the following actions:
To delete an existing host, select the check box next to the host and click DELETE.
To modify the settings for an existing host, select the check box next to the host, change
the desired information, and click APPLY.
Click Cancel to reset the data o the latest value of the switch.

Trap Logs

Use the Trap Logs screen to view information about the SNMP traps generated on the
switch.
The highest level warning level. If the device is down or not
.
The third-highest warning level. A critical log is saved if a critical
.
The lowest level of a device warning.
.
Provides the network administrators with device information.
Provides device information.
.
Provides detailed information about the log. Debugging must only be
Monitoring the System