Remote Diagnostics - NETGEAR GS752TP Software Administration Manual

Gigabit smart switches
Hide thumbs Also See for GS752TP:
Table of Contents

Advertisement

The following screen displays:
2.
In the IP Address/Hostname field, specify the IP address or the host name of the station you
want the switch to ping.
The initial value is blank. This information is not retained across a power cycle.
3.
Optionally, configure the following settings:
Probes Per Hop. Specify the number of times each hop must be probed. The valid
range is 1–10.
MaxTTL. Specify the maximum time-to-live for a packet in number of hops. The valid
range is 1–255.
InitTTL. Specify the initial time-to-live for a packet in number of hops. The valid range
is 1–255.
MaxFail. Specify the maximum number of failures allowed in the session. The valid
range is 0–255.
Interval. Specify the time between probes in seconds. The valid range is 1–60.
Port. Specify the UDP destination port in probe packets. The valid range is 1–65535.
Size. Specify the size of probe packets. The valid range is 64–1472.
4.
Click APPLY to initiate the traceroute. The results display in the Results field.

Remote Diagnostics

The Remote Diagnostics screen lets you enable Telnet for diagnostic purposes.
To configure the remote diagnostics feature:
1.
Select Maintenance
GS752TP, GS728TP, and GS728TPP Gigabit Smart Switches
Troubleshooting
Maintenance
Remote Diagnostics.
241