Parallel Installation; Corner Installation; Wall And Ceiling Clearances; Hearth Requirements - Vermont Castings SDDVTCBSB Installation & Operating Manual

Sddvt series stardance, direct vent gas heater
Table of Contents

Advertisement

Parallel Installation

Minimum Clearance and Flue Centerline
C
D
C L
B
Stove Clearances
ST128b
Pipe Centerlines
Stardance
Figure 3 - Parallel installation, minimum back and side
flue centerline
clearances, and flue centerlines.
9/28/00 djt

Corner Installation

Minimum Clearance and Flue Centerline
B
B
A
Stove Clearances
Pipe Centerlines
Figure 4 - Corner installation, minimum corner clearances
and flue centerline.
7
C L
A
A 4" (102 mm)
B 4" (102 mm)
C 15-1/2" (395 mm)
D 9" (229 mm)
A
A 4" (102 mm)
B 14-1/2" (370 mm)
ST129b
Stardance
corner specs
9/28/00 djt
Vermont Castings • Stardance SDDVTSB Installation Manual_R10 • 04/18
Wall Centerline from Floor
Direct Vent Only
A
Effective Minimum
Wall Thimble
Centerline
Figure 5 - Minimum wall centerline.
Wall & Ceiling Clearances
Direct Vent Only
C
A Rear Wall
ST101b
B Minimum Clearance
Stardance
Direct Vent
C Minimum Alcove Height
Min. Clrnc
D Maximum Alcove Depth
9/28/00 djt
Sidewall Clearance
* needed for installing DuraVent Minimum Vent Kit #2792 or HHT Minimum Vent Kit #SLP-FSSK.
Figure 6 - Dimensions and clearances to ceiling or alcove.

Hearth Requirements

The Stardance heater must be installed on rigid flooring.
When the heater is installed directly on any combustible
surface other than wood flooring, a metal or wood panel
extending the full width and depth of the unit must be used
as the hearth. There are no other hearth requirements.
ST131b
56" (1480 mm) (HHT Pipe)
Stardance
wall thimble
52" (1378 mm) DuraVent Pipe)
9/28/00 djt
D
B
A
4" (102 mm)
45-1/4" (1154 mm)
72" (1830 mm)
48" (1220 mm)
4" (102 mm)
3-90-20306760