NOTE: there will a 10 second delay for the flame
adjustment when the stove is turned on.
• When Set Temp. is 3° F or higher than Room Temp.,
flame height will be on High.
• When Set Temp. is 2° F higher than Room Temp., flame
height will be on Medium.
• When Set Temp. is 1° F higher than Room Temp., flame
height will be on Low.
• When Set Temp. is equal to Room Temp., flame height
does not change (stays on low).
• When Set Temp. is lower than Room Temp., the stove
will be shut off.
• When Set Temp. is 1° F higher than Room Temp., again
the flame height will be on Low.
• The fan speed follows the flame height, if the fan is
turned on.
To exit Smart Mode
thermostat and shut off the stove;
®
• Push and hold the THERMO buttons for 3 seconds, Or
• Press the OFF button, Or
• Slide down on the arrow buttons.
To shut off the Smart Mode
to regular thermostat mode, press and hold the THERMO
button and the ON/UP button at the same time for 3 seconds
again.
Blower Speed Control (Figure 69)
NOTE: Blower will only work with flame on.
The blower speed control function
is used to adjust the speed of the
blower connected to the Signature
Command System. There are four
speed levels, Off, Low, Medium,
High.
• Press the FAN button to enter
the blower speed control mode.
The fan icon will start flashing.
• Press the ON/up and OFF/down
button to increase/decrease the
blower speed.
• Press the fan button again to
confirm the speed setting. If the
stove is on, the blower speed will take effect right away;
if the stove is off, the receiver will remember this setting
and the blower is still off (see blower On Delay and Off
Delay in the next section).
• After the signal is sent, the ON/up and OFF/down buttons
become flame height controller again.
• When the fan button is flashing, slide up and down on
the arrow buttons will turn the blower speed to High
or Off directly without pressing the fan button again to
confirm.
42
thermostat option and return
®
Figure 69
FP2655
blower speed control
Vermont Castings • Stardance SDDVTSB Installation Manual_R10 • 04/18
• If the blower is turned on using the FAN button, the blower
speed will adjust automatically when using Smart Mode
thermostat (See Smart Mode
Blower On Delay Time and Off Delay Time Setup
Figure 70
• Hold the FAN button for 3 seconds until two numbers
appear on the LCD screen. The left number is blower On
Delay and the right number is blower Off Delay Time.
• When the first number is flashing, use the ON/up button to
set the desired On Delay Time from 0 to 15 min.
• Press the OFF/down button to jump to the Off Delay Time
setup.
• When the second number is flashing, use the ON/up
button again to set the desired Off Delay Time from 0 to
15 min.
• Press the OFF/down button again to finish the setup and
the new settings will be transmitted to the receiver.
• The default settings are 5 minutes for the On Delay Time
and 8 minutes for the Off Delay Time, as shown.
thermostat section).
®
Figure 70
FP2656
blower delay setup