Operating Instructions; Turning On The Stove; Command Center Operations - Vermont Castings SDDVTCBSB Installation & Operating Manual

Sddvt series stardance, direct vent gas heater
Table of Contents

Advertisement

Operating instructions

Turning on the stove

Turn on the master switch and wait for a beep. Press the ON
button on the Command Center or turn on wall switch. Pilot
will light and burner will come on High setting or last memory
setting (See Turning Off Stove below). For memory feature.
Pilot Safety Lockout Function
If the pilot doesn't light after sparking for 30 seconds, pilot trial
lockout happens. The LED on the Command Center flashes
Green once every 2 seconds, until reset.
If the pilot flame is lost during normal operation, the system
will try three (3) times to relight after three (3) failures, flame
loss lockout happens. The LED on the Command Center
flashes Red-Green once every 2 seconds, until reset.
Turning the master switch on the Command Center to the off
position, then ON again will reset the system.
Flame Height Control
Press the ON button (on the Command Center) once to turn
on the main burner with maximum flame height.
Press the OFF button to decrease flame height. The first
two presses will decrease the flame height to medium and
low. The third press on OFF will turn off the main burner. In
standing pilot configuration, the pilot will stay; in intermittent
pilot configuration, the pilot will be shut off.
Function
Operation
Power Up
Flip the master switch to the ON ("–")
position to power up the system
Stove ON
Press the ON s button on the Command
Center or turn on wall switch to turn the
stove on
Stove OFF
Flip the master switch to the OFF ("o")
position OR press the OFF t button 3 times
OR for Memory Off, hold the OFF t button
3 seconds, or turn off wall switch
Flame Height
Press the ON s button once to turn on the
Up
stove with maximum flame height
Flame Height
Press the OFF t button to lower the flame
Down
height to Medium and Low
Turning the Stove Off
There are three ways to turn the stove off.
1. Flip the master switch to the off ("O") position. (This will
turn the entire system OFF.)
2. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds or by
turning off the wall switch. These two commands of
OFF are (Memory Off) the system will remember all last
settings before turning off. The next time the stove is
turned on, all settings will resume. To reset, change to
the desired settings and shut off by using the Memory
Off commands and the system will be reset to those new
settings.
38
Vermont Castings • Stardance SDDVTSB Installation Manual_R10 • 04/18

Command Center Operations

The following functions are available on the Command
Center.
Self Diagnostics Chart
The Command Center has a self-diagnostic LED enabling
you to troubleshoot problems and potentially avoid a service
call. Please refer to the charts below for indicator reference.
Fault
Conversion Cover Missing
Spark Fail
Flame Error/Sensor Signal
Pilot Lockout - Trial
Pilot Lockout - Flame Loss
Low Battery
No or Low Thermopile Power
Vaccum Switch Failed (Power
Vent Only)
Learning
AC Power On
NOTE: Due to the sensitive temperature monitoring
components in the transmitter, it is necessary to allow
the transmitter to stabilize to room temperature before
accurate room temperatures are displayed. If the
transmitter is activated from a severe cold condition,
allow 15 minutes for accurate temperature readings to
appear on the LCD display.
!
Turn appliance OFF (at the Master Switch) if you are away
from your house for an extended period of time. Never leave
anything on top of the surface of the transmitter.
Function Areas of the LCD Display
Figure 59 shows the display of the TSFSC LCD.
Information Bar
The information bar shows the room temperature, the
"sending signal" radio icon, the low battery indication icon,
the child-proof icon, and the flame icon. This area doesn't
have touch buttons.
• The room temperature will always be shown after
power-up. It displays the room temperature from 40 °F
to 99 °F. "Lo" and "HI" will be displayed when the room
temperature is lower than 40°F or higher than 99°F,
respectively.
LED Indication
One RED every 7 seconds
Two RED every 7 seconds
Three RED every 7 seconds
Four RED every 7 seconds
Five RED every 7 seconds
One RED every 10 seconds
Two RED, every 10 seconds
One RED every 2 seconds until
reset
GREEN flashes, every 1 second
(for 10 seconds)
GREEN solid
WARNING
3-90-20306760