Junction Box Wiring

This should be done before framing the stove. Wire the
receptacle into an electrical circuit. Wire with minimum 60°
C wire in accordance with prevailing codes.
Remove the external junction box cover by removing the
screw from the side of the outside firebox wall. Junction box
was installed at the factory.
The junction box cover has a factory installed "romex" style
strain relief connector. After connecting the wires, route the
wire leads through this connector. Refer to the wiring diagram
in Figure 51.
Junction Box
Figure 51 - Junction Box Wiring Diagram

Command Center Wall Installation

The command center may be mounted on the wall with the
FP1912
use of the SCSWEK Kit (15ft. cable, junction box, wall cover).
Junction box wiring
Mount
the
junction
box
8/08
location on the wall. Do not extend beyond the 15 ft.
wire cable provided. If a longer distance is required,
the 15 ft. may be extended up to 30 ft. maximum by
using two (2) SCSWEK cables plugged together.
Route the wire from junction box to lower control area at
bottom of stove. Unplug the 12" cable from the command
center. Attach the connector to the pins from wire by pushing
in to connector making sure to follow the color code on
connector. Plug the 15 ft. extension cable into the 2 ft. cable.
Remove command center from the stove and plug the other
end of the extension cable into the command center. Snap
on wall cover provided and screw to junction box.

Wall Switch Installation

The wall switch wire connection is located off the 2 ft. wire
harness from the control box to the command center. Figure
52. The connection is labeled "Wall Switch". Unplug the male
and female connectors and connect the two (2) low voltage
wires provided. Run wire to desired location on wall. Up to
50 ft. of 18 ga. wire may be used if necessary. Attach wires
to wall switch. Mount the wall switch in to junction box and
screw on cover.
!
Do not connect wall switch to 110 V circuit.
27
120V AC
60Hz
Factory Supplied
Not Supplied
provided
at
the
desired
WARNING
Vermont Castings • Stardance SDDVTSB Installation Manual_R10 • 04/18
!
Electrical connections should only be performed by a
qualified, licensed electrician. Main power supply must
be turned off before connecting fans to the main electrical
power supply or performing service.
!
Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle.
Install the Fan – SDVTSC Models
It is easiest to install the fan kit before connecting a gas line.
• Unpack and inspect the blower assembly. Confirm that
the fan spins freely.
• Unfasten the two machine bolts attached to the lower
back of the stove (Figure 53).
• Using the two bolts, secure the blower assembly to the
rear of the stove (Figure 53).
• Connect the blower wires to the wire control board. See
Figure 55 on page 29.
Blower Assembly
Figure 52 - RADVTSC Blower assembly
Figure 53 - Secure Blower assembly to lower back of the stove.
ST147ED
RDV40 remove rear shroud
10/99
CAUTION
WARNING
ST473a
Fan parts
#2767 FK26
9/29/00
3-90-20306760