System Configuration/Setup
All System configuration/setup is done on the Command
Center. Choose the mode that best suits your needs.
NOTE: When using On/Off wall switch, the switch must
be in the ON position to perform all configuration set
ups at the command center.
Cold Climate Option
The Signature Command System is designed to operate in
either Standing Pilot or Intermittent Pilot mode.
• The Standing Pilot Mode is best for colder climates
when the pilot must remain on continuously to prevent
condensation and ensure reliable operation.
• The Intermittent Pilot Mode is ideal for maximum
efficiency, igniting the pilot only when needed to start
your stove, lowering fuel consumption and reducing your
carbon footprint.
Either mode benefits from the instantaneous battery back-up,
so you never have to worry about a power outage.
NOTE: The Signature Command System comes standard
in the Intermittent Pilot mode, so you must follow the
instructions below to switch to Standing Pilot Mode if
needed.
Intermittent/Standing Pilot Setup (Default intermittent)
Holding the ON button on the Command Center while turning
on the master switch will toggle between standing pilot and
intermittent pilot.
After the above operation, one beep (for standing pilot) or
two beeps (for intermittent pilot) will be given as confirmation.
Six-hour Safety Shutdown Option (Default ON)
The system comes preset from the factory with a six (6) hour
shutdown from its last command of operation. This is done to
prevent the stove from continuing to operate if unattended.
You may disable this feature if you wish.
NOTE: By disabling this feature, your stove may continue
to operate unattended.
Function
Intermittent / Standing Pilot Setup
Standing Pilot Temperature Shutoff
RF Remote Reciever On/Off
Learn Remote Transmitter
6-Hour Safety Shutdown Setup
37
Hold the ON p button while turning on the master switch
(Beep once for standing pilot, twice for intermittent pilot)
Hold the ON p button 3 seconds (when the master switch on
the main burner is off)
Push the RF receiver On/Off button on the control board.
Beep once for ON and beep twice for OFF
Hold the OFF q button while turning on the master switch
(Beep twice then press any handheld remote button)
Press the ON p button and OFF q button simultaneously
(Beep once for ON, twice for OFF)
Vermont Castings • Stardance SDDVTSB Installation Manual_R10 • 04/18
When the master switch is in the ON position ("-"), pressing
the ON button and the OFF button on the Command Center
simultaneously will toggle between enabling and disabling
the six-hour shutdown option.
After the above operation, one beep (for enabling the six-hour
shutdown option) or two beeps (for disabling the six-hour
shutdown option) will be given as confirmation.
Remote Transmitter Learn Function (Default OFF)
The RF receiver button located on the Control Board must
be in the on position before the learn function can begin. Use
paper clip to depress button. One beep for RF receiver ON or
two beeps for RF receiver OFF will be given as confirmation.
Refer to Figure 57 for location.
After the RF receiver is on, holding the OFF button on the
Command Center while turning on the master switch will
activate the learn function for the transmitter.
After the above operation, two beeps will be given and the
green LED on the Command Center will flash for 10 seconds.
During the 10 seconds, press the OFF button on a transmitter
to learn. Another two beeps will be given to confirm a
successful learning. Refer to transmitter instructions for
remote operations.
Shutting Off the Standing Pilot (Temporary Shut Off)
To shut off the standing pilot for service or summer shut down,
press and hold the ON button on the Command Center for
3 seconds when the master switch is in the ON position ("-")
and the main burner is off.
Note: Pilot will resume the next time system is turned on.
Key Combinations for System Settings
NOTE: When On/Off wall switch is used, it must be in the
On position to perform all system setups.
Operation
Default Setting
Intermittent Pilot
RF OFF
ON
3-90-20306760