Installation Requirements; Clearance Requirements - Vermont Castings SDDVTCBSB Installation & Operating Manual

Sddvt series stardance, direct vent gas heater
Table of Contents

Advertisement

Installation Requirements

The installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 – latest edition. (EXCEPTION: Do
not derate this appliance for altitude. Maintain the manifold
pressure at 3.5" w.c. for Natural Gas, and 10" w.c. for
Propane).
In Canada, installation must be in accordance with the current
CSA B-149.1 Installation Codes and/or local codes.
The installation should be done by a qualified service person
who is familiar with the building codes and installation
techniques appropriate for your area to accomplish a safe
and effective installation.
Your dealer or your local gas supplier will be able to refer a
qualified service person.
!
Due to high temperatures, the heater should be located
out of traffic and away from furniture and draperies.
The surface of the Heater Is hot when it is in use. Young
children should be watched carefully when they are in the
same room when the Heater is in use, and they should
be taught to avoid the hot surface. Keep any objects that
can burn well away from the Heater, and observe the
recommended clearances that follow.
DANGER
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and shall be installed.
In choosing a location for the stove, consider:
DANGER
• The location of outside walls;
• Where additional heat is needed:
• Where family members gather most often;
• The vent system requirements.
NOTE: We do not recommend the use of wallpaper next to
this stove. Over time, radiant heat may cause the wallpaper
to shrink, or may adversely affect the binders in the wallpaper
adhesive.
Une barrière visant à réduire le risque de brûlure
par le hublot chaude est fournie avec cet
appareil et doit être installé.
6
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Un panneau vitré chaud peut
causer des brûlures.
Laissez refroidir le panneau
vitré avant d'y toucher.
Ne laisser jamais les enfants
toucher le panneau vitré.
Vermont Castings • Stardance SDDVTSB Installation Manual_R10 • 04/18
Direct Vent System Only
A
E
A. Flat on corner wall
B. Room Divider
ST207a
C. Island
Stardance
Stove locations
Figure 2 - Possible stove locations.
9/28/00 djt

Clearance Requirements

Minimum Clearances to Combustible Materials
Measure side clearances as shown in Figures 3, 4 and 5
from the outer edge of the cast iron stove top. Measure rear
clearances from the outermost surface of the steel rear skirt.
The Stardance heater is approved for installation into
an alcove constructed of combustible materials to the
dimensions and clearances shown on the next page.
The same clearances apply in a standard parallel installation.
!
• Always maintain required clearances (air spaces) to
nearby combustibles to prevent fire hazard. Do not
fill air spaces with insulation. All venting components
must maintain a 1" (25 mm) clearance to combustible
materials. The gas appliance and vent system must
be vented directly to the outside of the building and
never be attached to a chimney serving a separate
solid fuel or gas-burning appliance.
• Refer to the manufacturer's instructions included
with the venting system for complete installation
procedures.
D
B
C
D. Cross Corner
E. Flat on wall
WARNING
3-90-20306760

Hide quick links:

Advertisement

Table of Contents
loading