Opt. Blower
Opt. Aux.
300 Watt
Max.
NOTE: Wall switch wires
must be connected together
if a wall switch is not being used.
Figure 95 - Signature Command Wiring Diagram
Figure 96 - Blower Wiring Diagram
54
A/C MODULE
TO JUNCTION BOX
IN FIREPLACE
WHITE
BLACK
BLACK
WHITE
GREEN
Control Board
Conversion
NG/LP
Plug-in Connector
Stepper Motor to
Control Board
Ground
DC Power/Green
Plug-in Connector
Control Board to
Solenoid
Gas In
To Junction Box
In Fireplace
{
Light
WHITE
BLACK
WHITE
{
BLACK
BLACK
Optional
RADVTSC
WHITE
AUX
SCS 2 wire wiring
FP2684
BLOTSDVSC fan wiring
Vermont Castings • Stardance SDDVTSB Installation Manual_R10 • 04/18
RF Receiver
ON/OFF Button
Black / Thermopile
Red / Thermopile
Sensor
Ignitor / Sparker
Plug-in Connector
Control Board to Command Center
LED
OFF/LO
ON/HI
Master Switch
Command Center
Gas Out
Pilot Gas Tubing
Valve
GREEN
Connector
Pin To Contro l Box
Pilot
Optional
Wall Switch
3-90-20306760