Vertical Termination; Restrictor Plate Adjustment For Extended Pipe Runs - Vermont Castings SDDVTCBSB Installation & Operating Manual

Sddvt series stardance, direct vent gas heater
Table of Contents

Advertisement

Vertical Termination

A vertical vent system must terminate no less than 8' (2.44 m)
and no more than 40' (12 m) above the appliance flue collar. A
restrictor plate (supplied) must be used, where specified, in all
vertically terminated vent systems. (Refer to Figure 8) NOTE:
The restrictor plate supplied with the vertical termination
should be discarded. Adjust the restrictor plate according to
recommendations in Figure 10. A vertically terminated vent
system must also conform to the following criteria:
• No more than three 90° elbows may be used.
• Two 45° elbows may be substituted for one 90° elbow.
No more than six 45° elbows may be used.
• Vent must rise a minimum of 2 feet (305 mm) before
offset is used.
• Termination height must conform to roof clearance as
specified in Figure 11.
40
39
38
37
All Vertical
36
Terminations in this
35
area Require use
34
of the Restrictor
33
Plate*
32
31
30
29
28
27
Vertical terminations
26
must be within this
25
area
24
23
22
21
20
19
18
16
15
14
13
12
11
10
9
8
7
6
5
4
**
3
2
1
0
1
2
3
4
5
6
Horizontal Run (in feet)
**No Restrictor Plate
Figure 8 - Vertical vent termination window.
9
Unacceptable
Venting Configuration
7
8 9
10 11 12 13 14 15 16 17 18 19
Vermont Castings • Stardance SDDVTSB Installation Manual_R10 • 04/18

Restrictor Plate Adjustment for Extended Pipe Runs

The Stardance stove is shipped with a restrictor plate in
the Parts Bag. Adjustments can be made by loosening the
adjustment screw to allow the restrictor plate to slide up or
down. (Figure 9) A guide for usage is shown in Figure 10.
NOTE: Some installations may require some adjustment
by the installer for optimum flame appearance. Optimum
flame appearance is a flame that is not subject to tall, dirty
yellow flames producing soot or flames lifting off of the
ember bed ports.
Restrictor Plate Adjustment
• Remove the screw in the back wall of the firebox.
• Install restrictor plate as shown in Figure 9 with cut out
on left side. Secure with adjustment screw.
• Measure from center of screw to top edge of diverter
(Figure 9) to adjust plate according to guidelines in
Figure 10.
• Tighten attachment screw.
• Install logs following log installation instructions.
Restrictor Plate
ST132a
FDV28
Vertical
vent run
12/3/99 djt
Figure 9 - Loosen screw to adjust restrictor plate.
Examples for Extended Run/Restrictor Plate Settings
Vertical 20'
(6 m), 90°
elbow, out 8'
(2.4 m)
Restrictor plate measurement from top of plate to
center of screw:
20
2
" (70 mm)
3
4
from center
of screw to
top edge of
plate
Figure 10
ST936
SDDVT restrictor plate
Vertical 11'
Vertical 40'
6/07
(3.4 m), 90°
(12 m)
elbow, out 2'
(610 mm)
Plate down
Plate down
to top of slot
to top of slot
Vertical 5'
(1.5 m), 90°
elbow, out 5'
(1.5 m)
2
" (60 mm)
3
8
from center
of screw to
top edge of
plate
3-90-20306760