Vertical Through-The-Roof Application/Installation - Vermont Castings SDDVTCBSB Installation & Operating Manual

Sddvt series stardance, direct vent gas heater
Table of Contents

Advertisement

Wall Screws
and Anchors
Snorkel
Termination Cap
4" Clearance
Gravel
Drain
Window Well
Figure 35 - Snorkel kit installation.

Vertical Through-The-Roof Application/installation

For all vertical through-the-roof installations, the supplied
flue restrictors must be installed. Install the flue restrictor
according to the settings shown in the Vertical Through-the-
Roof Installation Flue Restrictor Chart in order to balance the
airflow in and out of the unit and to maintain proper flame
height.
This gas stove has been approved for:
• Vertical installations up to 40' (12 m) in height. Up to a
10' (3 m) horizontal vent run can be installed within the
vent system using a maximum of two 90° elbows. Figure
38
• Up to two 45° elbows may be used within the horizontal
run. For each 45° elbow used on the horizontal plane,
the maximum horizontal length must be reduced by 18"
(450 mm).
Example: Maximum horizontal length:
No elbows
= 10' (3 m)
1 x 45° elbow = 8.5' (2.6 m)
2 x 45° elbows = 7' (2.1 m)
• A minimum of an 8' (2.5 m) vertical rise is required.
(Figure 38)
• Two sets of 45° elbow offsets may be used within the
vertical sections. From 0 to a maximum of 8' (2.5 m) of
vent pipe can be used between elbows. Figure 38
22
Waterproof Seal
Around Pipe
Firestop
RADIANCE
ST653
install snorkel
4/20/01 djt
Vermont Castings • Stardance SDDVTSB Installation Manual_R10 • 04/18
• SLP-HVS supports offsets. This application will require
that you first determine the roof pitch and use the
appropriate starter kit. (Refer to Venting Components
list.)
• The maximum angular variation allowed in the system is
270°. Figure 39
• For the minimum height of the vent above the highest
point of penetration through the roof refer to Figure 40.
Vertical Through-the-Roof Installation
Flue Restrictor Setting Chart
Vertical Run
8-12 Feet of Pipe
(2.4 -3.7 m)
12-40 Feet of Pipe
(3.7 - 12 m)
Figure 36 - Flue Restrictor Set at Medium Restriction
FP3042
restrictor 75
Figure 37 - Flue Restrictor Set at Maximum Restriction
FP3043
restrictor 100
Restrictor Setting
Medium Restriction
(Figure 36)
Maximum Restriction
(Figure 37)
3-90-20306760