Vermont Castings Stardance SDDVT Series Installation & Operating Manual
Vermont Castings Stardance SDDVT Series Installation & Operating Manual

Vermont Castings Stardance SDDVT Series Installation & Operating Manual

Direct vent gas heater
Hide thumbs Also See for Stardance SDDVT Series:

Advertisement

Installation & Operating Manual
Installation and Appliance Setup - Care and Operation
INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Call your dealer for questions on Installation, Operation, or Service.
NOTICE: SAVE THESE INSTRUCTIONS
SDDVT Series Stardance
Direct Vent Gas Heater
Models:
SDDVT-IFT-BD, SDDVT-IFT-BM,
SDDVT-IFT-BS, SDDVT-IFT-CB, SDDVTCBSB,
SDDVTBSSB, SDDVTBDSB, SDDVTBMSB
CERTIFIED
S
B
AFETY
ARRIER
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
11
®
12734
Stardance Dv
cover
8/07
Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21
!
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death or property damage.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use
any phone in your building.
– Leave the building immediately.
– Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
– If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
DANGER
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this
appliance and must be installed.
WARNING
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
3-90-30007467

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings Stardance SDDVT Series

  • Page 1 HHT Factory Trained or NFI certified professionals. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed. Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 2: Table Of Contents

    PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. Verify proper operation after servicing. * Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer. Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 4: California Safety Information

    248 CMR 5.08(2)(a)1 through 4. Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 5: Framing And Clearances

    The dimensions included are for planning, layout and design purposes only. Final holes for the venting system and any other permanent modifications to the dwelling must only be completed with the unit in the final installed position. Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 6: Installation Requirements

    This appliance is for use only with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 7: Hearth Requirements

    *Needed for installing DuraVent Minimum Vent Kit #2792 or HHT Minimum Vent Kit #SLP-FSSK. Figure 2.6 - Dimensions and clearances to ceiling or alcove. Figure 2.4 - Corner installation, minimum corner clearances. ST129b Stardance corner specs 01/19 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 8: Gas Specifications

    Refer to this manual for correct installation and operational pro- cedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier. Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 9 Note: Numbering system starts with 1 on the bottom Figure 2.10 10 11 12 13 14 15 16 17 18 19 Horizontal Run (in feet) **No Restrictor Plate Figure 2.8 - Vertical vent termination window. Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 10 For installations using DuraVent pipe, parallel installations with minimum wall clearance have restricted access for connecting the Horizontal Vent Cap straps to the vent pipe. See the maker’s instructions for recommended installation procedures. 1010 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 11: Chimney Diagram

     Only permitted if veranda, porch, deck or balcony is fully open requirements. on a minimum 2 sides beneath the floor. 1111 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 12 3. All gravity air intakes within 3’ (914 mm) of a termination cap must be a minimum of 1’ (305 mm) below the termination cap. Figure 2.12 - Termination clearances. 1212 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 13: Assembly And Installation

    (152 mm) Straight pipe section has an effective length of Freestanding Draft Hood Adapter FSDHAGSLP 4-1/2” (115 mm). SL Snorkel Cap (Includes 1 pair of firestops) SLK-SNKD *CCSLP adapter is required when using HHT components. 1313 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 14: Assembling The Stove

    Read all instructions before starting installation, then follow these instructions carefully to maximize stove performance and safety. Report damaged parts to your dealer. 1414 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 15 Items required for installation: Tools: Phillips screwdriver Hammer Saw and/or saber saw Level Measuring Tape Electric drill and bits Pliers Square Building Supplies: Framing materials Wall finishing materials Caulking Material (noncombustible) 1515 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 16 If slip section seals are broken during removal of the termination cap, vent may leak. CORRECT INCORRECT Figure 3.3 - Make sure the seams are not aligned to prevent unintentional disconnection. 1616 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 17 Figure 3.8 - Rotate Seams for Disassembly edges of cap. When installing a horizontal termination cap, follow the cap location guidelines as prescribed by current ANSI Z223.1 and CAN/CGA-B149 installation codes. 1717 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 18 2” (51 mm) (or the distance required if installing a second 90° elbow), Figure 3.13. NOTE: Always install vertical side wall horizontal venting with a 1/4” rise for every 12” of run. 1818 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 19 Figure 3.15 - Use extension brackets to mount snorkel against Termination Cap recessed wall. Figure 3.14 - Horizontal Termination Cap on a Vinyl Siding Wall SLP Cap ST219 snorkel detail 12/6/99 djt 1919 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 20 • The maximum angular variation allowed in the system is 270°, Figure 3.18 ST933 • For the minimum height of the vent above the highest point of penetration through the roof, Figure 3.18. Selkirk vertical venting 6/07 2020 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 21 Replace component parts of the chimney and fireplace (Included in Link-Stove Kit) as specified by the professionals. 4” Flex Pipe Sheet Metal Screws (Included in Link-Stove Kit) Figure 3.20 2121 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 22 7. The connection between the appliance and the retro connector may be completed with sections of direct vent pipe. 2222 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 23: Log Set Installation

    NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed. 2323 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 24: Thermostat Connection

    Terminate these leads power supply or performing service. with 1/4" female connectors. 2. Connect the thermostat or wall switch wires to the valve, Figure 3.30. 2424 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 25 Vermont Castings Fuel GAS SUPPLY ONLY BY A QUALIFIED GAS SERVICE Conversion Kit. TECHNICIAN. FOLLOW ALL LOCAL CODES. THERE MUST BE A GAS SHUT-OFF BETWEEN THE STOVE AND THE SUPPLY. 2525 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 26: Sddvt-Ift Wiring Requirements

    IFT-RC400 REMOTE CONTROL TO JUNCTION BOX 110-120 VAC GROUND 3 PRONG 110VAC RF MODULE 6 PIN 6V DC BATTERY PACK SPLITTER ROCKER SWITCH Figure 3.31 - SDDVT-IFT Wiring Diagram 2626 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 27: Install The Safety Barrier

    NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and must be installed. 2727 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 28: Operating Instructions

    Turn clockwise counterclockwise to decrease to increase flame height flame height CO105d Figure 4.3 - Flame adjustment knob for SIT valve. Pilot flame FP390 6/07 djt FLAME ADJUSTMENT KNOB 11/21/96 2828 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 29: Lighting And Operating Instructions

    4. Push in gas control knob slightly and turn clockwise 2. Turn off all electric power to the stove if service is to be to “OFF". Do not force. performed. 5. Close control access panel. 2929 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 30: Troubleshooting

    (high) causing and thermocouple. the pilot safety to drop out 2. Possible blockage of the 2. Check the vent terminal for blockage (recycling the flue gases) vent terminal 3030 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 31 D. Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water. 3131 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 32: Lighting Instructions (Ift)

    For additional information on operating your Keep burner and control compartment clean. See installation and operating instructions Hearth & Home Technologies fi replace, please 593-913K accompanying appliance. refer to www.hearthnhome.com. 3232 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 33: Operation During A Power Outage - Intellifire

    • Slide the ON/REMOTE/OFF switch to the ON position NOTICE: Some functionality will be lost when using battery backup including remote control, fan, lights, or any other auxiliary functions that require household 110-120 VAC power 3333 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 34: Detailed Component Operating Instructions

    2. If multiple control options are installed, the IFT-ECM will respond to the last command from the wired wall switch or IFT-RC400. The wired wall switch is NOT available if a Power Vent is used. 3434 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 35 • ON/OFF Functions • Flame height adjustments • Thermostat • Cold Climate Feature • Fan Speed Please refer to the instructions included with the remote control for more detailed operating instructions. 3535 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 36: Frequently Asked Questions

    90 seconds. If this failure appliance did not start. Try again period of appliance inactivity. persists, contact dealer for service. by pressing Flame On. Gas control system failure. 3636 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 37: Troubleshooting

    40 ohms. If open or shorted, replace valve. Check valve harness wire continuity, if open replace 6-pin harness. Pilot won’t light, there is no noise or spark, Spark coil failure. Replace ECM. 2 Red/2 Green Lockout. 3737 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 38 Damaged pilot assembly. Check resistance between tip of sense rod and IFT-ECM connector, should be less than 1 ohm. Replace pilot assembly if damage is detected. 3838 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 39: Burner, Pilot & Control Compartment

    If the flame is blue and candle-like in appearance, adjust glass or add more glass over ports. NOTE: The type of installation, vent system configuration, and wind effects may cause the flame patterns to vary. Figure 4.6 - Correct pilot and burner flame appearance. CO105d Pilot flame 6/07 djt 3939 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 40: Cleaning And Maintenance

    CAUTION Turn the pilot off before painting. Allow the heater to cool completely before painting. Figure 5.2 - Release the latches to remove the glass frame. 4040 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467 ST208...
  • Page 41: Gasket Replacement

    Do not use your stove if the flame pattern differs from that 5.1 & 5.2. To remove the old gasket, use a razor blade shown here. Contact your Vermont Castings dealer or a to separate the glass and gasket from the frame, and qualified technician for help.
  • Page 42: Wiring Diagrams

    NOTE: If any of the original wire, as supplied with the appliance, must be replaced, it must be replaced with type SF-2, 200°C wire or its equivalent. St124c Thermostat RHEOSTAT / SNAPSTAT Chassis Ground wiring 1/11/00 djt Figure 6.2 - Fan circuit. ST153 rdv connections diag. 10/99 4242 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 43 SENSE REMOTE CONTROL TO JUNCTION BOX 110-120 VAC GROUND 3 PRONG 110VAC RF MODULE 6 PIN 6V DC BATTERY PACK SPLITTER ROCKER SWITCH Figure 6.3 - SDDVT-IFT Wiring Diagram 4343 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 44: Service Parts List

    Direct Vent Gas Heater Ending Manufacturing Date: Active With Standing Pilot Ignition SDDVTCBSB (Classic Black) SDDVTBMSB (Majolica Brown) SDDVTBSSB (Biscuit) SDDVTBDSB (Bordeaux) 19 20 Part number list on following page. 10/21 4444 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 45 Nut, Hex Jam 3/8-16 TOPLK-Z Pkg of 10 1203290-10 Pawl Assembly, Ash Door 30002362 Front Steel Handle/Shaft - NI/VER 30002717 Restrictor Plate 20013026 Additional service parts on following page 4545 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 46 Touch-Up Paint Biscuit 0001277 Majolica 0001270 Control Plate Assembly (Burner, Valve, Pilot) 20012493 Finish Bag SRV30007263 Conversion Kits Conversion Kit, NG to LP LPK-SDDVT-SP Conversion Kit, LP to NG 4604-012 4646 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 47 Ending Manufacturing Date: Active Direct Vent Gas Heater w/IFT Controls SDDVT-IFT-CB (Classic Black) SDDVT-IFT-BM (Majolica Brown) SDDVT-IFT-BD (Bordeaux) SDDVT-IFT-BS (Biscuit) 15 14 Part number list on following page. 07/21 4747 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 48 Pawl Assembly, Ash Door 30002362 Nut, Hex Jam 3/8-16 TOPLK-Z Pkg of 10 1203290-10 Glass Frame Assembly 30000127 Gasket, Glass (Medium Knit) 1203702K Glass 1601691 Additional service parts on following page 4848 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 49 20307738K Finish Bag SRV30007263 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 250v, 3A fuse, 3/4” long Additional service parts on following page 4949 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 50 Biscuit SRV30003226 Majolica SRV30004852 Shelf Clip Qty 2 req 1409035 Hardware Pack 30007019K Conversion Kits NG to Propane LPK-SDDVT-IFT Conversion Kit Propane to NG SRV30007469 NGK-DXV-50 Regulator Propane SRVLPK-DXV-50 5050 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 51: Optional Accessories

    2. Position the shelf and adjust the brackets so the shelf RCB,RCMT TSST, RCST fits correctly. 3. Tighten the screws. Refer to the instructions included with each warming shelf for complete installation procedures. 5151 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 52: Warranty Policy

    Firebox and heat exchanger, FlexBurn® System 3 years Lifetime (engine, inner cover, access cover and fireback) None 1 Year All purchased replacement parts Page 1 of 2 4021-645L 10/20 5252 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 53 EXPRESSED WARRANTY SPECIFIED ABOVE FOR THE APPLICABLE PRODUCT. Some States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Page 2 of 2 4021-645L 10/20 5353 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...
  • Page 54 Based on CSA P.4.1-2015 EFFICIENCY RATINGS ENERGUIDE RATINGS D.O.E. STOVE EFFICIENCY MODEL PERCENTAGE (AFUE PERCENTAGE) SDDVT Series 58.4 66.5 SDDVT-IFT Series 63.3 66.5 352 Mountain House Road • Halifax, PA 17032 www.vermontcastings.com 5454 Vermont Castings • Stardance SDDVT Installation Manual_R23 • 11/21 3-90-30007467...

Table of Contents