Agilent Technologies 35670A Installation Manual page 35

Hide thumbs Also See for 35670A:
Table of Contents

Advertisement

Agilent 35670A
Schematic and Parts List for Notch Filter
The Harmonic Distortion performance test requires either an HP 339A or an
HP 3326A or HP 3325A/B with notch filter. The following shows the schematic and
parts list for the notch filter.
Reference
Description
0.025 µF ±2.5%, 100 V polypropelene-metalized
C1 - C4
249 Ω ±1% metal film, 0.125 W
R1 - R2
118 Ω ±1% metal film, 0.125 W
R3
20 Ω trimmer, 1 turn
R4 - R6
Specifications
Recommended Test Equipment
HP Part Number
HP 0160-6809
HP 0698-4421
HP 0698-4407
HP 2100-3409
1-19