Programming example: End point and radius specification
N5 G90 X30 Y40
N10 G2 X50 Y40 CR=12.207
N o te
With a negative leading sign for the value with CR=-..., a circular segment larger than a semi-circle is selected.
Programming example: Definition of end point and aperture angle
N5 G90 X30 Y40
N10 G2 X50 Y40 AR=105
96
; Starting point circle for N10
; End point and radius
; Starting point circle for N10
; End point and aperture angle
Programming and Operating Manual (Milling)