Siemens SIPROTEC Manual page 716

Line differential protection with distance protection
Hide thumbs Also See for SIPROTEC:
Table of Contents

Advertisement

Appendix
A.8 Information List
No.
Description
1310
>Earth Fault O/C Instantaneous
trip (>EF InstTRIP)
1311
>E/F Teleprotection ON (>EF
Teleprot.ON)
1312
>E/F Teleprotection OFF (>EF
TeleprotOFF)
1313
>E/F Teleprotection BLOCK (>EF
TeleprotBLK)
1318
>E/F Carrier RECEPTION,
Channel 1 (>EF Rec.Ch1)
1319
>E/F Carrier RECEPTION,
Channel 2 (>EF Rec.Ch2)
1320
>E/F Unblocking: UNBLOCK,
Channel 1 (>EF UB ub 1)
1321
>E/F Unblocking: BLOCK,
Channel 1 (>EF UB bl 1)
1322
>E/F Unblocking: UNBLOCK,
Channel 2 (>EF UB ub 2)
1323
>E/F Unblocking: BLOCK,
Channel 2 (>EF UB bl 2)
1324
>E/F BLOCK Echo Signal (>EF
BlkEcho)
1325
>E/F Carrier RECEPTION,
Channel 1, Ph.L1 (>EF Rec.Ch1
L1)
1326
>E/F Carrier RECEPTION,
Channel 1, Ph.L2 (>EF Rec.Ch1
L2)
1327
>E/F Carrier RECEPTION,
Channel 1, Ph.L3 (>EF Rec.Ch1
L3)
1328
>E/F Unblocking: UNBLOCK
Chan. 1, Ph.L1 (>EF UB ub 1-L1)
1329
>E/F Unblocking: UNBLOCK
Chan. 1, Ph.L2 (>EF UB ub 1-L2)
1330
>E/F Unblocking: UNBLOCK
Chan. 1, Ph.L3 (>EF UB ub 1-L3)
1331
Earth fault protection is switched
OFF (E/F Prot. OFF)
1332
Earth fault protection is
BLOCKED (E/F BLOCK)
1333
Earth fault protection is ACTIVE
(E/F ACTIVE)
1335
Earth fault protection Trip is
blocked (EF TRIP BLOCK)
1336
E/F phase selector L1 selected
(E/F L1 selec.)
1337
E/F phase selector L2 selected
(E/F L2 selec.)
1338
E/F phase selector L3 selected
(E/F L3 selec.)
1345
Earth fault protection PICKED UP
(EF Pickup)
1354
E/F 3I0>>> PICKED UP (EF
3I0>>>Pickup)
1355
E/F 3I0>> PICKED UP (EF 3I0>>
Pickup)
716
Function
Type
of In-
for-
matio
n
Earth Fault O/C
SP
on
off
Teleprot. E/F
SP
*
Teleprot. E/F
SP
*
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Teleprot. E/F
SP
on
off
Earth Fault O/C
OUT
on
off
Earth Fault O/C
OUT
on
off
Earth Fault O/C
OUT
*
Earth Fault O/C
OUT
on
off
Earth Fault O/C
OUT
*
Earth Fault O/C
OUT
*
Earth Fault O/C
OUT
*
Earth Fault O/C
OUT
*
Earth Fault O/C
OUT
*
Earth Fault O/C
OUT
*
Log Buffers
Configurable in Matrix
on off
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
on
*
LED BI
*
*
LED
on off
*
LED
*
*
LED
on off
*
LED
on off
*
LED
on off
*
LED
on off
*
LED
off
*
LED
on
*
LED
on
*
LED
C53000-G1176-C169-5, Release date 02.2011
IEC 60870-5-103
BO
166
10
1
Yes
BO
BO
BO
166
13
1
Yes
BO
166
18
1
Yes
BO
166
19
1
Yes
BO
166
20
1
Yes
BO
166
21
1
Yes
BO
166
22
1
Yes
BO
166
23
1
Yes
BO
166
24
1
Yes
BO
166
25
1
Yes
BO
166
26
1
Yes
BO
166
27
1
Yes
BO
166
28
1
Yes
BO
166
29
1
Yes
BO
166
30
1
Yes
BO
166
31
1
Yes
BO
166
32
1
Yes
BO
166
33
1
Yes
BO
BO
BO
BO
BO
166
45
2
Yes
BO
BO
SIPROTEC, 7SD5, Manual