Line differential protection with distance protection
Hide thumbs Also See for SIPROTEC:
Table of Contents

Advertisement

Table 2-21
Operational measured values of the local device
Measured Values
; I
; I
Phase currents
I
L1
L2
L3
I
Sensitive earth current
EE
3I
Earth current
0
-I
), ϕ(I
-I
),
Phase angle of the phase currents
ϕ(I
L1
L2
L2
L3
-I
)
towards each other
ϕ(I
L3
L1
I
, I
Positive and negative sequence cur-
1
2
rents
I
, I
Transformer starpoint current or earth
Y
P
current of the parallel line
U
, U
, U
Phase-to-phase voltages
L1-L2
L2-L3
L3-L1
U
, U
, U
Phase-earth voltage
L1-E
L2-E
L3-E
3U
Displacement voltage
0
-U
), ϕ(U
-U
),
Phase angle of the phase voltages
ϕ(U
L1
L2
L2
L3
-U
)
towards each other
ϕ(U
L3
L1
-I
), ϕ(U
-I
),
Phase angle of the phase voltages
ϕ(U
L1
L1
L2
L2
-I
)
towards the phase currents
ϕ(U
L3
L3
U
, U
Positive and negative sequence
1
2
component of the voltages
U
; U
Voltage at measuring input U
X
EN
U
Voltage at measuring input U
sy2
U
Positive sequence component of volt-
1compound
ages at the remote end (if compound-
ing is active in voltage protection)
R
, R
,
Operational resistance of all loops
L1-E
L2-E
R
, R
,
L3-E
L1-L2
R
, R
,
L1-L2
L3-L1
X
, X
,
Operational reactance of all loops
L1-E
L2-E
X
, X
,
L3-E
L1-L2
X
, X
,
L2-L3
L3-L1
S, P, Q
Apparent, active and reactive power
cos ϕ
Power factor
f
Frequency (constellation frequency)
, Θ
,
Thermal value of each phase,
Θ
L1
TRIP
L2
TRIP
referred to the tripping value
Θ
L3
TRIP
Resulting thermal value,
Θ/Θ
TRIP
referred to the tripping value, calculat-
ed according to the set method
U
, U
, U
Measured voltage values
sy1
sy2
diff
(for synchronsim check)
f
, f
, f
Measured frequency values
sy1
sy2
diff
(for synchronism check)
Amount of phase angle difference
ϕ
Diff
between line and busbar
(for synchronism check)
1)
according to address 1104
2)
according to address 1103
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
Primary Secondary
A
A
A
mA
A
A
°
A
A
A
A
kV
V
kV
V
kV
V
°
°
kV
V
V
4
kV
V
4
kV
V
Ω
Ω
Ω
Ω
MVA,
MW,
MVAR
(abs)
(abs)
Hz
Hz
%
%
kV
Hz
°
2.26 Additional Functions
% Referred to
Nominal operational current
Nominal operational current
Nominal operational current
Nominal operational current
Nominal operational current
Nominal operational voltage
Nominal operational voltage / √3
Nominal operational voltage / √3
Nominal operational voltage / √3
Operational rated voltage or
Operational rated voltage / √3
Operational rated voltage / √3
·I
Nominal operational
√3·U
N
N
quantities
Nominal frequency
Trip overtemperature
Trip overtemperature
Functions
1)
3)1)
1)
1)
3)1)
2)
2)
2)
2)
2)4)5)
2)
1)2)
473