No.
Description
289
Alarm: Current summation super-
vision (Failure Σi)
290
Alarm: Broken current-wire de-
tected L1 (Broken Iwire L1)
291
Alarm: Broken current-wire de-
tected L2 (Broken Iwire L2)
292
Alarm: Broken current-wire de-
tected L3 (Broken Iwire L3)
295
Broken wire supervision is
switched OFF (Broken wire OFF)
296
Current summation superv is
switched OFF (Σi superv. OFF)
297
Broken current-wire at other end
L1 (ext.Brk.Wire L1)
298
Broken current-wire at other end
L2 (ext.Brk.Wire L2)
299
Broken current-wire at other end
L3 (ext.Brk.Wire L3)
301
Power System fault
(Pow.Sys.Flt.)
302
Fault Event (Fault Event)
303
E/Flt.det. in isol/comp.netw. (E/F
Det.)
320
Warn: Limit of Memory Data ex-
ceeded (Warn Mem. Data)
321
Warn: Limit of Memory Parameter
exceeded (Warn Mem. Para.)
322
Warn: Limit of Memory Operation
exceeded (Warn Mem. Oper.)
323
Warn: Limit of Memory New ex-
ceeded (Warn Mem. New)
351
>Circuit breaker aux. contact:
Pole L1 (>CB Aux. L1)
352
>Circuit breaker aux. contact:
Pole L2 (>CB Aux. L2)
353
>Circuit breaker aux. contact:
Pole L3 (>CB Aux. L3)
356
>Manual close signal (>Manual
Close)
357
>Block manual close cmd. from
external (>Blk Man. Close)
361
>Failure: Feeder VT (MCB
tripped) (>FAIL:Feeder VT)
362
>Failure: Usy4 VT (MCB tripped)
(>FAIL:U4 VT)
366
>CB1 Pole L1 (for AR,CB-Test)
(>CB1 Pole L1)
367
>CB1 Pole L2 (for AR,CB-Test)
(>CB1 Pole L2)
368
>CB1 Pole L3 (for AR,CB-Test)
(>CB1 Pole L3)
371
>CB1 READY (for AR,CB-Test)
(>CB1 Ready)
378
>CB faulty (>CB faulty)
379
>CB aux. contact 3pole Closed
(>CB 3p Closed)
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
Function
Type
of In-
for-
matio
n
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
*
Measurem.Superv
OUT
*
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
P.System Data 2
OUT
ON
OFF
P.System Data 2
OUT
*
P.System Data 2
OUT
ON
OFF
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
P.System Data 2
SP
*
P.System Data 2
SP
*
P.System Data 2
SP
*
P.System Data 2
SP
*
P.System Data 2
SP
on
off
P.System Data 2
SP
on
off
P.System Data 2
SP
on
off
P.System Data 2
SP
*
P.System Data 2
SP
*
P.System Data 2
SP
*
P.System Data 2
SP
*
P.System Data 2
SP
*
P.System Data 2
SP
*
Log Buffers
Configurable in Matrix
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
ON
*
ON
*
*
ON
*
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
*
*
LED BI
Appendix
A.8 Information List
IEC 60870-5-103
BO
135
250
1
Yes
BO
135
137
1
Yes
BO
135
138
1
Yes
BO
135
139
1
Yes
BO
BO
BO
BO
BO
135
231
2
Yes
135
232
2
No
BO
BO
BO
BO
BO
150
1
1
Yes
BO
150
2
1
Yes
BO
150
3
1
Yes
BO
150
6
1
Yes
BO
150
7
1
Yes
BO
192
38
1
Yes
BO
150
12
1
Yes
BO
150
66
1
Yes
BO
150
67
1
Yes
BO
150
68
1
Yes
BO
150
71
1
Yes
BO
BO
150
78
1
Yes
711