A.7 Settings
Addr.
Parameter
3755
T Uph-e<<
3758
CURR.SUP. Uphe<
3759A
Uph-e<(<) RESET
3761
Uph-ph<(<)
3762
Uph-ph<
3763
T Uph-ph<
3764
Uph-ph<<
3765
T Uphph<<
3768
CURR.SUP.Uphph<
3769A
Uphph<(<) RESET
3771
U1<(<)
3772
U1<
3773
T U1<
3774
U1<<
3775
T U1<<
3778
CURR.SUP.U1<
3779A
U1<(<) RESET
3802
START
3805
Paral.Line Comp
3806
Load Compensat.
3807
two ended
3811
Tmax OUTPUT BCD
3901
FCT BreakerFail
3902
I> BF
3903
1p-RETRIP (T1)
3904
T1-1pole
3905
T1-3pole
3906
T2
3907
T3-BkrDefective
3908
Trip BkrDefect.
3909
Chk BRK CONTACT
3912
3I0> BF
3913
T2StartCriteria
3921
End Flt. stage
3922
T-EndFault
702
Function
C
Voltage Prot.
0.00 .. 100.00 sec; ∞
Voltage Prot.
ON
OFF
Voltage Prot.
1.01 .. 1.20
Voltage Prot.
OFF
Alarm Only
ON
U<Alarm U<<Trip
Voltage Prot.
1.0 .. 175.0 V; 0
Voltage Prot.
0.00 .. 100.00 sec; ∞
Voltage Prot.
1.0 .. 175.0 V; 0
Voltage Prot.
0.00 .. 100.00 sec; ∞
Voltage Prot.
ON
OFF
Voltage Prot.
1.01 .. 1.20
Voltage Prot.
OFF
Alarm Only
ON
U<Alarm U<<Trip
Voltage Prot.
1.0 .. 100.0 V; 0
Voltage Prot.
0.00 .. 100.00 sec; ∞
Voltage Prot.
1.0 .. 100.0 V; 0
Voltage Prot.
0.00 .. 100.00 sec; ∞
Voltage Prot.
ON
OFF
Voltage Prot.
1.01 .. 1.20
Fault Locator
Pickup
TRIP
Fault Locator
NO
YES
Fault Locator
NO
YES
Fault Locator
ON
OFF
Fault Locator
0.10 .. 180.00 sec
Breaker Failure
ON
OFF
Breaker Failure
1A
0.05 .. 20.00 A
5A
0.25 .. 100.00 A
Breaker Failure
NO
YES
Breaker Failure
0.00 .. 30.00 sec; ∞
Breaker Failure
0.00 .. 30.00 sec; ∞
Breaker Failure
0.00 .. 30.00 sec; ∞
Breaker Failure
0.00 .. 30.00 sec; ∞
Breaker Failure
NO
with T1-trip
with T2-trip
w/ T1/T2-trip
Breaker Failure
NO
YES
Breaker Failure
1A
0.05 .. 20.00 A
5A
0.25 .. 100.00 A
Breaker Failure
With exp. of T1
Parallel withT1
Breaker Failure
ON
OFF
Breaker Failure
0.00 .. 30.00 sec; ∞
Setting Options
Default Setting
1.00 sec
ON
1.05
OFF
50.0 V
2.00 sec
17.0 V
1.00 sec
ON
1.05
OFF
30.0 V
2.00 sec
10.0 V
1.00 sec
ON
1.05
Pickup
YES
NO
ON
0.30 sec
ON
0.10 A
0.50 A
YES
0.00 sec
0.00 sec
0.15 sec
0.00 sec
NO
YES
0.10 A
0.50 A
Parallel withT1
OFF
2.00 sec
C53000-G1176-C169-5, Release date 02.2011
Comments
T Uph-e<< Time Delay
Current supervision (Uph-e)
Uph-e<(<) Reset ratio
Operating mode Uph-ph under-
voltage prot.
Uph-ph< Pickup
T Uph-ph< Time Delay
Uph-ph<< Pickup
T Uph-ph<< Time Delay
Current supervision (Uph-ph)
Uph-ph<(<) Reset ratio
Operating mode U1 undervolt-
age prot.
U1< Pickup
T U1< Time Delay
U1<< Pickup
T U1<< Time Delay
Current supervision (U1)
U1<(<) Reset ratio
Start fault locator with
Mutual coupling parall.line com-
pensation
Load Compensation
two ended fault location
Maximum output time via BCD
Breaker Failure Protection
Pick-up threshold I>
1pole retrip with stage T1 (local
trip)
T1, Delay after 1pole start (local
trip)
T1, Delay after 3pole start (local
trip)
T2, Delay of 2nd stage (busbar
trip)
T3, Delay for start with defective
bkr.
Trip output selection with defec-
tive bkr
Check Breaker contacts
Pick-up threshold 3I0>
T2 Start Criteria
End fault protection
Trip delay of end fault protection
SIPROTEC, 7SD5, Manual