Siemens SIPROTEC Manual page 694

Line differential protection with distance protection
Hide thumbs Also See for SIPROTEC:
Table of Contents

Advertisement

Appendix
A.7 Settings
Addr.
Parameter
2656
T 3I0p Add
2660
IEC Curve
2661
ANSI Curve
2670
I(3I0)p Tele/BI
2671
I(3I0)p SOTF
2801
DMD Interval
2802
DMD Sync.Time
2811
MinMax cycRESET
2812
MiMa RESET TIME
2813
MiMa RESETCYCLE
2814
MinMaxRES.START
2901
MEASURE. SUPERV
2902A
BALANCE U-LIMIT
2903A
BAL. FACTOR U
2904A
BALANCE I LIMIT
2905A
BAL. FACTOR I
2906A
ΣI THRESHOLD
2907A
ΣI FACTOR
2908A
T BAL. U LIMIT
2909A
T BAL. I LIMIT
2910
FUSE FAIL MON.
2911A
FFM U>(min)
2912A
FFM I< (max)
2913A
FFM U<max (3ph)
2914A
FFM Idelta (3p)
2915
V-Supervision
2916A
T V-Supervision
2921
T mcb
2931
BROKEN WIRE
694
Function
C
Back-Up O/C
0.00 .. 30.00 sec
Back-Up O/C
Normal Inverse
Back-Up O/C
Very Inverse
Extremely Inv.
LongTimeInverse
Back-Up O/C
Inverse
Back-Up O/C
Short Inverse
Long Inverse
Moderately Inv.
Very Inverse
Extremely Inv.
Definite Inv.
Back-Up O/C
NO
YES
Back-Up O/C
NO
YES
Demand meter
15 Min., 1 Sub
15 Min., 3 Subs
15 Min.,15 Subs
30 Min., 1 Sub
60 Min., 1 Sub
Demand meter
On The Hour
15 After Hour
30 After Hour
45 After Hour
Min/Max meter
NO
YES
Min/Max meter
0 .. 1439 min
Min/Max meter
1 .. 365 Days
Min/Max meter
1 .. 365 Days
Measurem.Superv
ON
OFF
Measurem.Superv
10 .. 100 V
Measurem.Superv
0.58 .. 0.95
Measurem.Superv
1A
0.10 .. 1.00 A
5A
0.50 .. 5.00 A
Measurem.Superv
0.10 .. 0.95
Measurem.Superv
1A
0.10 .. 2.00 A
5A
0.50 .. 10.00 A
Measurem.Superv
0.00 .. 0.95
Measurem.Superv
5 .. 100 sec
Measurem.Superv
5 .. 100 sec
Measurem.Superv
ON
OFF
Measurem.Superv
10 .. 100 V
Measurem.Superv
1A
0.10 .. 1.00 A
5A
0.50 .. 5.00 A
Measurem.Superv
2 .. 100 V
Measurem.Superv
1A
0.05 .. 1.00 A
5A
0.25 .. 5.00 A
Measurem.Superv
w/ CURR.SUP
w/ I> & CBaux
OFF
Measurem.Superv
0.00 .. 30.00 sec
Measurem.Superv
0 .. 30 ms
Measurem.Superv
ON
OFF
Alarm only
Setting Options
Default Setting
0.00 sec
Normal Inverse
Inverse
NO
NO
60 Min., 1 Sub
On The Hour
YES
0 min
7 Days
1 Days
ON
50 V
0.75
0.50 A
2.50 A
0.50
0.25 A
1.25 A
0.50
5 sec
5 sec
ON
30 V
0.10 A
0.50 A
15 V
0.10 A
0.50 A
w/ CURR.SUP
3.00 sec
0 ms
OFF
C53000-G1176-C169-5, Release date 02.2011
Comments
T 3I0p Additional Time Delay
IEC Curve
ANSI Curve
Instantaneous trip via Tele-
prot./BI
Instantaneous trip after Switch-
OnToFault
Demand Calculation Intervals
Demand Synchronization Time
Automatic Cyclic Reset Function
MinMax Reset Timer
MinMax Reset Cycle Period
MinMax Start Reset Cycle in
Measurement Supervision
Voltage Threshold for Balance
Monitoring
Balance Factor for Voltage
Monitor
Current Balance Monitor
Balance Factor for Current
Monitor
Summated Current Monitoring
Threshold
Summated Current Monitoring
Factor
T Balance Factor for Voltage
Monitor
T Current Balance Monitor
Fuse Failure Monitor
Minimum Voltage Threshold U>
Maximum Current Threshold I<
Maximum Voltage Threshold U<
(3phase)
Delta Current Threshold
(3phase)
Voltage Failure Supervision
Delay Voltage Failure Supervi-
sion
VT mcb operating time
Fast broken current-wire supervi-
sion
SIPROTEC, 7SD5, Manual