Siemens SIPROTEC Manual page 646

Line differential protection with distance protection
Hide thumbs Also See for SIPROTEC:
Table of Contents

Advertisement

Appendix
A.1 Ordering Information and Accessories
Line Differential
Protection
With Distance
Protection
Three-pole tripping, without automatic reclosure, without synchronism check
Three-pole tripping, with automatic reclosure, without synchronism check
Single-/three-pole tripping, without automatic reclosure, without synchronism check
Single-/three-pole tripping, with automatic reclosure, without synchronism check
Three-pole tripping, without automatic reclosure, with synchronism check
Three-pole tripping, with automatic reclosure, with synchronism check
Single-/three-pole tripping, without automatic reclosure, with synchronism check
Single-/three-pole tripping, with automatic reclosure, with synchronism check
With protection data interface 2, see Additional Specification N
Additional Specification N for functions and protection data interface 2
Three-pole tripping, without automatic reclosure, without synchronism check
Three-pole tripping, with automatic reclosure, without synchronism check
Single-/three-pole tripping, without automatic reclosure, without synchronism check
Single-/three-pole tripping, with automatic reclosure, without synchronism check
Three-pole tripping, without automatic reclosure, with synchronism check
Three-pole tripping, with automatic reclosure, with synchronism check
Single-/three-pole tripping, without automatic reclosure, with synchronism check
Single-/three-pole tripping, with automatic reclosure, with synchronism check
1-/3-pole tripping, with automatic reclosure, with synchronism check
Port E: FO5 optical, 820 nm, 2 ST connectors, length of optical fibre up to 1.5 km,
for FO direct connection or communication networks using multimode fibre
Port E: FO6 optical, 820 nm, 2 ST connectors, length of optical fibre up to 3.5 km,
for FO direct connection using multimode fibre
Port E: FO17 optical, 1300 nm, LC duplex connector, length of optical fibre up to 24 km,
for FO direct connection using monomode fibre
Port E: FO18 optical, 1300 nm, LC duplex connector, length of optical fibre up to 60 km,
for FO direct connection using monomode fibre
Port E: FO19 optical, 1550 nm, LC duplex connector, length of optical fibre up to 100 km,
for FO direct connection using monomode fibre
Port E: FO30 optical, 820 nm, 2 ST connectors, length of optical fibre up to 1.5 km,
for FO direct connection or communication networks with IEEE C37.94 interface using multimode
2)
fibre
1)
for surface-mounting housing, delivery with external repeater
2)
This interface is not available in the surface-mounting housing (MLFB position 9 = E/G/H/Q/R).
646
5
6
7
S
D
5
Functions 1 and Port E: Protection Data Interface 2
(Port E) (only if Pos. 13 = 9)
1)
1)
1)
7
8
9
10 11 12
13 14 15 16
Pos. 25
0
1
2
3
4
5
6
7
8
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
+
N
Pos. 13
0
1
2
3
4
5
6
7
9
Pos. 26
A
B
G
H
J
S

Advertisement

Table of Contents
loading

Table of Contents