Line differential protection with distance protection
Hide thumbs Also See for SIPROTEC:
Table of Contents

Advertisement

Addr.
Parameter
3437
ADT SynRequest
3438
T U-stable
3440
U-live>
3441
U-dead<
3450
1.AR: START
3451
1.AR: T-ACTION
3453
1.AR Tdead 1Flt
3454
1.AR Tdead 2Flt
3455
1.AR Tdead 3Flt
3456
1.AR Tdead1Trip
3457
1.AR Tdead3Trip
3458
1.AR: Tdead EV.
3459
1.AR: CB? CLOSE
3460
1.AR SynRequest
3461
2.AR: START
3462
2.AR: T-ACTION
3464
2.AR Tdead 1Flt
3465
2.AR Tdead 2Flt
3466
2.AR Tdead 3Flt
3467
2.AR Tdead1Trip
3468
2.AR Tdead3Trip
3469
2.AR: Tdead EV.
3470
2.AR: CB? CLOSE
3471
2.AR SynRequest
3472
3.AR: START
3473
3.AR: T-ACTION
3475
3.AR Tdead 1Flt
3476
3.AR Tdead 2Flt
3477
3.AR Tdead 3Flt
3478
3.AR Tdead1Trip
3479
3.AR Tdead3Trip
3480
3.AR: Tdead EV.
3481
3.AR: CB? CLOSE
3482
3.AR SynRequest
3483
4.AR: START
3484
4.AR: T-ACTION
3486
4.AR Tdead 1Flt
3487
4.AR Tdead 2Flt
3488
4.AR Tdead 3Flt
3489
4.AR Tdead1Trip
3490
4.AR Tdead3Trip
3491
4.AR: Tdead EV.
3492
4.AR: CB? CLOSE
3493
4.AR SynRequest
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
Function
C
Auto Reclose
YES
NO
Auto Reclose
0.10 .. 30.00 sec
Auto Reclose
30 .. 90 V
Auto Reclose
2 .. 70 V
Auto Reclose
YES
NO
Auto Reclose
0.01 .. 300.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
0.01 .. 300.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
0.01 .. 300.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Auto Reclose
0.01 .. 300.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec; ∞
Auto Reclose
0.01 .. 1800.00 sec
Auto Reclose
YES
NO
Auto Reclose
YES
NO
Setting Options
Default Setting
NO
0.10 sec
48 V
30 V
YES
0.20 sec
1.20 sec
1.20 sec
0.50 sec
1.20 sec
0.50 sec
1.20 sec
NO
NO
NO
0.20 sec
1.20 sec
1.20 sec
0.50 sec
∞ sec
0.50 sec
1.20 sec
NO
NO
NO
0.20 sec
1.20 sec
1.20 sec
0.50 sec
∞ sec
0.50 sec
1.20 sec
NO
NO
NO
0.20 sec
1.20 sec
1.20 sec
0.50 sec
∞ sec
0.50 sec
1.20 sec
NO
NO
Appendix
A.7 Settings
Comments
Request for synchro-check after
3pole AR
Supervision time for dead/live
voltage
Voltage threshold for live line or
bus
Voltage threshold for dead line or
bus
Start of AR allowed in this cycle
Action time
Dead time after 1phase faults
Dead time after 2phase faults
Dead time after 3phase faults
Dead time after 1pole trip
Dead time after 3pole trip
Dead time after evolving fault
CB ready interrogation before re-
closing
Request for synchro-check after
3pole AR
AR start allowed in this cycle
Action time
Dead time after 1phase faults
Dead time after 2phase faults
Dead time after 3phase faults
Dead time after 1pole trip
Dead time after 3pole trip
Dead time after evolving fault
CB ready interrogation before re-
closing
Request for synchro-check after
3pole AR
AR start allowed in this cycle
Action time
Dead time after 1phase faults
Dead time after 2phase faults
Dead time after 3phase faults
Dead time after 1pole trip
Dead time after 3pole trip
Dead time after evolving fault
CB ready interrogation before re-
closing
Request for synchro-check after
3pole AR
AR start allowed in this cycle
Action time
Dead time after 1phase faults
Dead time after 2phase faults
Dead time after 3phase faults
Dead time after 1pole trip
Dead time after 3pole trip
Dead time after evolving fault
CB ready interrogation before re-
closing
Request for synchro-check after
3pole AR
699