Addr.
Parameter
1632
R(Z4) Ø-Ø
1633
X(Z4)
1634
RE(Z4) Ø-E
1635
T4 DELAY
1641
Op. mode Z5
1642
R(Z5) Ø-Ø
1643
X(Z5)+
1644
RE(Z5) Ø-E
1645
T5 DELAY
1646
X(Z5)-
1651
Op. mode Z1B
1652
R(Z1B) Ø-Ø
1653
X(Z1B)
1654
RE(Z1B) Ø-E
1655
T1B-1phase
1656
T1B-multi-phase
1657
1st AR -> Z1B
1661
Op. mode Z6
1662
R(Z6) Ø-Ø
1663
X(Z6)+
1664
RE(Z6) Ø-E
1665
T6 DELAY
1666
X(Z6)-
1701
Op. mode Z1
690
Function
C
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. Quadril.
1A
0.050 .. 250.000 Ω
5A
0.010 .. 50.000 Ω
Dis. General
0.00 .. 30.00 sec; ∞
Dis. Quadril.
Dis. MHO
Dis. Quadril.
Forward
Reverse
Non-Directional
Inactive
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. General
0.00 .. 30.00 sec; ∞
Dis. Quadril.
Dis. MHO
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. Quadril.
Forward
Reverse
Non-Directional
Inactive
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. General
0.00 .. 30.00 sec; ∞
Dis. Quadril.
Dis. MHO
Dis. General
0.00 .. 30.00 sec; ∞
Dis. Quadril.
Dis. MHO
Dis. General
NO
Dis. Quadril.
YES
Dis. MHO
Dis. Quadril.
Forward
Reverse
Non-Directional
Inactive
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. General
0.00 .. 30.00 sec; ∞
Dis. Quadril.
Dis. MHO
Dis. Quadril.
1A
0.050 .. 600.000 Ω
5A
0.010 .. 120.000 Ω
Dis. MHO
Forward
Reverse
Inactive
Setting Options
Default Setting
12.000 Ω
2.400 Ω
12.000 Ω
2.400 Ω
12.000 Ω
2.400 Ω
0.90 sec
Inactive
12.000 Ω
2.400 Ω
12.000 Ω
2.400 Ω
12.000 Ω
2.400 Ω
0.90 sec
4.000 Ω
0.800 Ω
Forward
1.500 Ω
0.300 Ω
3.000 Ω
0.600 Ω
3.000 Ω
0.600 Ω
0.00 sec
0.00 sec
NO
Inactive
15.000 Ω
3.000 Ω
15.000 Ω
3.000 Ω
15.000 Ω
3.000 Ω
1.50 sec
4.000 Ω
0.800 Ω
Forward
C53000-G1176-C169-5, Release date 02.2011
Comments
R(Z4), Resistance for ph-ph-
faults
X(Z4), Reactance
RE(Z4), Resistance for ph-e
faults
T4 delay
Operating mode Z5
R(Z5), Resistance for ph-ph-
faults
X(Z5)+, Reactance for Forward
direction
RE(Z5), Resistance for ph-e
faults
T5 delay
X(Z5)-, Reactance for Reverse
direction
Operating mode Z1B (overrreach
zone)
R(Z1B), Resistance for ph-ph-
faults
X(Z1B), Reactance
RE(Z1B), Resistance for ph-e
faults
T1B-1phase, delay for single ph.
faults
T1B-multi-ph, delay for multi ph.
faults
Z1B enabled before 1st AR (int.
or ext.)
Operating mode Z6
R(Z6), Resistance for ph-ph-
faults
X(Z6)+, Reactance for Forward
direction
RE(Z6), Resistance for ph-e
faults
T6 delay
X(Z6)-, Reactance for Reverse
direction
Operating mode Z1