Appendix
A.8 Information List
No.
Description
169
VT Fuse Failure (alarm >10s) (VT
FuseFail>10s)
170
VT Fuse Failure (alarm instanta-
neous) (VT FuseFail)
171
Failure: Phase Sequence (Fail
Ph. Seq.)
177
Failure: Battery empty (Fail Bat-
tery)
181
Error: A/D converter (Error A/D-
conv.)
183
Error Board 1 (Error Board 1)
184
Error Board 2 (Error Board 2)
185
Error Board 3 (Error Board 3)
186
Error Board 4 (Error Board 4)
187
Error Board 5 (Error Board 5)
188
Error Board 6 (Error Board 6)
189
Error Board 7 (Error Board 7)
190
Error Board 0 (Error Board 0)
191
Error: Offset (Error Offset)
192
Error:1A/5Ajumper different from
setting (Error1A/5Awrong)
193
Alarm: Analog input adjustment
invalid (Alarm adjustm.)
194
Error: Neutral CT different from
MLFB (Error neutralCT)
196
Fuse Fail Monitor is switched
OFF (Fuse Fail M.OFF)
197
Measurement Supervision is
switched OFF (MeasSup OFF)
234.2100
U<, U> blocked via operation
(U<, U> blk)
273
Set Point Phase L1 dmd> (SP.
IL1 dmd>)
274
Set Point Phase L2 dmd> (SP.
IL2 dmd>)
275
Set Point Phase L3 dmd> (SP.
IL3 dmd>)
276
Set Point positive sequence
I1dmd> (SP. I1dmd>)
277
Set Point |Pdmd|> (SP. |Pdmd|>) Set Points(MV)
278
Set Point |Qdmd|> (SP. |Qdmd|>) Set Points(MV)
279
Set Point |Sdmd|> (SP. |Sdmd|>) Set Points(MV)
285
Power factor alarm (cosϕ alarm)
710
Function
Type
of In-
for-
matio
n
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
Measurem.Superv
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Device
OUT
on
off
Measurem.Superv
OUT
*
Measurem.Superv
OUT
on
off
Voltage Prot.
IntSP
on
off
Set Points(MV)
OUT
on
off
Set Points(MV)
OUT
on
off
Set Points(MV)
OUT
on
off
Set Points(MV)
OUT
on
off
OUT
on
off
OUT
on
off
OUT
on
off
Set Points(MV)
OUT
on
off
Log Buffers
Configurable in Matrix
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
C53000-G1176-C169-5, Release date 02.2011
IEC 60870-5-103
BO
135
188
1
Yes
BO
BO
192
35
1
Yes
BO
135
193
1
Yes
BO
135
178
1
Yes
BO
135
171
1
Yes
BO
135
172
1
Yes
BO
135
173
1
Yes
BO
135
174
1
Yes
BO
135
175
1
Yes
BO
135
176
1
Yes
BO
135
177
1
Yes
BO
135
210
1
Yes
BO
BO
135
169
1
Yes
BO
135
181
1
Yes
BO
135
180
1
Yes
BO
135
196
1
Yes
BO
135
197
1
Yes
BO
BO
BO
BO
BO
BO
BO
BO
BO