Cisco ASR 1013 Hardware Installation Manual page 683

Asr 1000 series
Hide thumbs Also See for ASR 1013:
Table of Contents

Advertisement

Troubleshooting Initial Startup Problems
Symptom
System does not power on.
System powers off, no STATUS
LED, and no operating fans.
Possible Cause
DC internal power cables are not
fully seated on the terminal block.
Power source is faulty.
Faulty power cable.
Faulty power supply.
Power supply failure.
Cisco ASR 1000 Series Router Hardware Installation Guide
Troubleshooting the Power Subsystem
Possible Solution
Check that all ground cables are
properly seated in the terminal
block on the DC power supply.
Turn the power source switch off,
connect the power cable to another
power source, if available, and turn
the router power switch back on.
Turn the router power switch to the
standby position (|), (for DC power,
also turn the circuit breaker to the
Off position and tape it to that
position), remove the cable and
replace it.
If the system still fails to come up
when the power supply is
connected to a different power
source with a new power cable, the
power supply is probably faulty.
Contact a service representative.
**If the system is operating with
only one power supply, it powers
off after five minutes.
649

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents